Chapter 5: Error Messages and Troubleshooting
35
Cannot read labels
When the appliance tries to initialize a
new file system, it has a problem
reading the disk labels it wrote to the
disks.
This problem can be because the
system failed to read the disk size, or
the written disk labels were invalid
Contact Network Appliance Customer
Support.
Disk label processing
failed
The appliance detects that the disk is
not in the correct drive bay.
Make sure that the disk is in the
correct bay.
Halted: firmware too
old
The disk firmware is an old version.
Update the disk firmware by entering
the following command:
disk_fw_update
No disks
The system cannot detect any SCSI
disks.
Verify that all disks are properly seated
in the drive bays.
Drive %s.%d not
supported
%s—
The disk number;
%d—
The disk ID number. The system
detects an unsupported disk drive.
1.
Remove the drive immediately or
the system drops down to the
PROM monitor within 30
seconds.
2.
Check the System Configuration
Guide at
http://now.netapp.com
to
verify support for your disk drive.
Halted: Illegal
configuration
Incorrect cluster configuration.
1.
Check the console for details.
2.
Verify that all cables are correctly
connected.
Boot error message
Explanation
Corrective action
Summary of Contents for C1200 NetCache
Page 10: ...x Preface...