Operational error messages
Power %a status OK
<current reading>
<range>
A power voltage is back to a normal
condition from a warning or critical
condition.
No action needed.
Power %a outside
normal functioning
voltage levels but
within critical range
<current reading>
<range>
A power voltage is outside noncritical
limits but within critical limits.
If the condition persists, replace the
identified power supply, as described
in “
Replacing the power supplies
” on
page 89.
Power %a POWER
SUPPLY FAILED!!
<current reading>
<range>
Shutting down the
system because of
Power %a POWER
SUPPLY FAILED!!
A power voltage is outside the critical
limit. The system shuts down.
Replace the power supply, as
described in “
Replacing the power
supplies
” on page 89.
Power Supply %a:
<event>
One of the following events occurred
at a power supply:
◆
A power supply was removed
◆
A power supply failed
◆
Predictive failure of a power
supply
◆
Current to the power supply was
lost
Check the power supply for the failed
conditions, then replace it, as
described in “
Replacing the power
supplies
” on page 89, if needed.
Power Supply %a:
<event> deasserted
<Power Supply %a>:
state normal
The power supply is back to a normal
operating conditions.
No action needed.
Error message
Explanation
Corrective action