Chapter 5: Error Messages and Troubleshooting
43
“Power Unit:
<event>”
One of the following events was
detected at the power unit sensor:
◆
Power off
◆
Power cycle
◆
AC lost
◆
AC lost deasserted (restored)
Check the power and correct any
conditions or replace the power
supply, as described in “
Replacing the
power supplies
” on page 89.
“Power Unit
Redundancy: <event>”
One of the following events was
detected at the power unit redundancy
sensor:
◆
Redundancy lost
◆
Redundancy regained
POST error: POST
error message or
number
A POST error was detected at the
POST error sensor.
See “
Startup error messages
” on
page 24 for information about the
displayed error.
Critical Interrupt:
<event>
A bus error was detected at the
critical interrupt sensor.
Report the problem to Network
Appliance Customer Support.
Memory: <event>
One of the following events was
detected at the memory sensor:
◆
Correctable ECC
◆
Uncorrectable ECC
Report the problem to Network
Appliance Customer Support.
SCSI Voltage
Performance: <event>
One of the following events was
detected at the SCSI voltage
performance sensor:
◆
Performance lags
◆
Performance met
No action needed.
Error message
Explanation
Corrective action
Summary of Contents for C1200 NetCache