Chapter 6: Maintenance and Servicing
85
Replacing the fans
Replacing power supply fans
Removing the
power supply
chassis on the
C2100
The power supply fan is integrated into the power supply chassis. If the power
supply fan fails, you must replace the power supply chassis. To remove the power
supply chassis from the C2100, complete the following steps, using the figure for
reference.
Step
Action
1
Open the appliance, as described in “
Opening the appliance
” on
page 65.
2
Remove both power supplies, as described in “
Removing a power
supply from the C2100
” on page 89.
3
Remove the ATA Flex cable retaining bracket, located on the
backplane, then disconnect the copper-colored ATA Flex cable from
the SCSI backplane.
4
Remove the cooling fan block, as described in“
Replacing chassis
fans
” on page 82.