![background image](http://html1.mh-extra.com/html/network-appliance/fas200-series/fas200-series_hardware-and-service-manual_1675390100.webp)
88
Replacing the battery on the CPU module
5
Install the new battery by placing it into the battery housing, and
secure the battery housing to the CPU module using the four screws.
6
Reconnect the battery wire to the CPU module.
7
Reinstall the CPU module. See “
Procedures for installing the CPU
8
After turning on your system, run diagnostics on the new battery. See
the
Diagnostics Guide
for more information.
Note
The battery is rechargeable, and diagnostics might indicate a low
charge after installation. This is normal. The battery begins charging
automatically after you boot Data ONTAP.
9
Check and set the date and time values on your appliance. Replacing
the battery will likely cause these values to get reset.
Step
Action
Summary of Contents for FAS200 Series