![background image](http://html1.mh-extra.com/html/network-appliance/fas200-series/fas200-series_hardware-and-service-manual_1675390117.webp)
Chapter 5: Error Messages and Troubleshooting
105
monitor.chassis
PowerSupplies.
ok
INFO
This message
indicates that
all power
supplies are
OK.
No corrective
action needed.
LOG_INFO:
Chassis power
supplies OK
#396:
Chassis
power
supplies
OK
monitor.chassis
PowerSupply.of
f
NOTICE
ps_number
INT
This message
indicates that
a power
supply is
turned off.
Turn the power
supply on.
LOG_NOTICE:
Chassis power
supply off
#395:
Chassis
power
supply is
off
monitor.chassis
PowerSupply.
notPresent
NOTICE
ps_number
INT
This message
indicates that
a power
supply is not
present.
Add a power
supply to the
appliance.
LOG_NOTICE:
Chassis power
supply not
present
#394:
Chassis
power
supply is
not present
monitor.chassis
PowerSupply.
degraded
NOTICE
ps_number
reasonText
INT
STRING
This message
indicates that
a power
supply is
degraded.
A replacement
power supply
might be required.
Contact technical
support for
further
instruction.
LOG_NOTICE:
Chassis power
supply is
degraded
#392:
Chassis
power
supply is
degraded
monitor.chassis
Power.ok
NOTICE
This messages
indicates that
the
motherboard
power is OK.
No corrective
action needed.
LOG_NOTICE:
Chassis power
is OK
#406:
Chassis
power is
OK
Name
Parameters
Description
Corrective
action
Syslog
SNMP