![background image](http://html1.mh-extra.com/html/network-appliance/fas200-series/fas200-series_hardware-and-service-manual_1675390036.webp)
24
Connecting additional disk shelves
8
Cable the disk shelf LRC B, ESH2 B, or AT-FCX B module Output
port of your second disk shelf to the LRC B, ESH2 B, or AT-FCX B
module Input port of your third disk shelf. Cable the disk shelf LRC A,
ESH2 A, or AT-FCX A module Output port of your second disk shelf
to the LRC A, ESH2 A, or AT-FCX A module Input port of your third
disk shelf. Make sure that the cable connections on both disk shelves
are tight.
9
Attach the grounding cable between shelves, as shown in the
illustration.
10
Set the disk shelf ID switch on your third disk shelf to 3, and set the
disk shelf loop speed to 1 Gb, as described in Step 5.