52
Configuring the Fibre Channel port
For more
information
For more information about configuring your SAN, see the following resources:
◆
Fibre Channel Tape SAN Solutions at
http://www.netapp.com/osn/info/config.html
◆
Data
ONTAP System Administration FCP Block Access Management Guide
3
After the reboot, verify that port 0c is in initiator mode by entering the following command:
sysconfig
Example:
fas270a> sysconfig
NetApp Release RscrimshawN_030824_2300: Mon Aug 25 02:20:04 PDT 2003
System ID: 0084165669 (fas270a); partner ID: 0084165671 (fas270b)
System Serial Number: 379589 (fas270a)
slot 0: System Board
Processors: 2
Processor revision: B2
Processor type: 1250
Memory Size: 1022 MB
slot 0: FC Host Adapter 0b
14 Disks: 952.0GB
1 shelf with EFH
slot 0: FC Host Adapter 0c
slot 0: SB1250-Gigabit Dual Ethernet Controller
e0a MAC Address: 00:a0:98:00:d5:90 (100tx-fd-up)
e0b MAC Address: 00:a0:98:00:d5:91 (auto-unknown-cfg_down)
slot 0: NetApp ATA/IDE Adapter 0a (0x00000000000001f0)
0a.0 122MB
Note
Fibre Channel port 0c is identified as FC Host Adapter 0c.
4
Enable port 0c by entering the following command.
storage enable adapter 0c
Example:
fas270a> storage enable adapter 0c
Mon Dec 8 08:55:09 GMT [rc:notice]: Onlining Fibre Channel adapter 0c.
host adapter 0c enable succeeded
Step
Action
Summary of Contents for FAS200 Series