![background image](http://html1.mh-extra.com/html/network-appliance/fas200-series/fas200-series_hardware-and-service-manual_1675390083.webp)
Chapter 4: Replacing FAS200 Series Devices
71
2
Put on the antistatic wrist strap and attach the grounding leash to the
appliance chassis.
3
Disconnect all cables to the CPU module that you are replacing.
4
At the rear-center of your appliance, using your thumb and index
finger of both hands, press the cam mechanism levers in the middle
of the CPU module to release it.
The following figure shows how to release the cam mechanism.
5
Carefully pull the cam handle so that the CPU module slides out
from the chassis. The CPU module has a travel distance of
approximately 10 inches (25.4 centimeters).