96
Startup error messages
Startup error messages
Startup sequence
When you apply power to your appliance, it verifies the hardware that is in the
system, loads the operating system, and displays the Power-On Self-Test (POST)
messages on the system console.
POST messages
POST is a series of tests run from the motherboard PROM. These tests check the
hardware on the motherboard and differ depending on your system configuration.
The following series of messages are examples of POST messages displayed on
the console.
Header:
CFE version 1.1.0 based on Broadcom CFE: 1.0.35
Copyright (C) 2000,2001,2002,2003 Broadcom Corporation.
Portions Copyright (C) 2002,2003 Network Appliance Corporation.
POST messages:
HyperTransport: 400MHz
CPU type 0x1040102: 650MHz
Total memory: 0x40000000 bytes (1024MB)
Starting AUTOBOOT press any key to abort...
Loading: Failed.
Loading: 0xffffffff80001000/8604573 Entry at 0xffffffff80..
Starting program at 0xffffffff80001000
Press CTRL-C for special boot menu
Note
If the messages are not appearing on your system console, verify that you are
using the DB-9 to RJ-45 adapter.