Replacing the CPU module
Replacing the CPU module
Removing the CPU module
Removing the CPU
module
To remove the CPU module, complete the following steps.
Step
Actions
1
If you are performing…
Then…
A planned CPU module
replacement on a FAS250
or a nonclustered
FAS270
Shut down the appliance by entering the
following command at the console:
halt
Caution
Always use the
halt
command to
perform a clean shutdown.
An unplanned CPU
module replacement on a
FAS250 or a
nonclustered FAS270
If possible, shut down the appliance by
entering the following command at the
console:
halt
Caution
Use the
halt
command to perform a
clean shutdown whenever possible.
A planned CPU module
replacement on a
clustered FAS270c
Determine which module is to be
replaced. From the partner CPU
module, perform a takeover operation
by entering the following command:
cf takeover
An unplanned CPU
module replacement on a
clustered FAS270c,
where the partner node
did or did not perform a
takeover
Proceed to
.