SDI-IP-GTW User Manual
19
2.3
Power
2.3.1
AC Power Supply
Warning:
This product should be operated only from the type of power
source indicated on the marking label. Please consult a qualified
electrical engineer or your local power company if you are not sure of
the power supply to your business.
The SDI-IP-GTW provides a wide-ranging power supply covering a rate
voltage range 100-240Vac, 50/60Hz. Please refer to Technical
Specification for a detailed specification of the power supply.
2.3.2
Power Cable and Earthing
2.3.2.1
General
Ensure that the AC power cable is suitable for the country in which the
unit is to be operated.
Warning:
If the moulded plug fitted to the mains cable supplied with
this unit is not required, please dispose of it safely. Failure to do this
may endanger life as live ends may be exposed if the removed plug is
inserted into a mains outlet.
Caution:
Power supply cords should be routed so that they are not
likely to be walked on or pinched by items placed upon or against
them, paying particular attention to cords at plugs, convenience
receptacles, and the point where they exit from the appliance.
The unit is supplied with a two meter detachable mains supply cable
equipped with the moulded plug suitable for Europe, UK or US.
The wires in the mains cable are coloured in accordance with the wire
colour code shown in Table 3.
Table 3. Supply Cable wiring colours
UK (BS 1363)
EUROPE (CEE 7/7)
USA (NEMA 5-15P)
Earth:
Green-and yellow
Green-and yellow
Green
Neutral:
Blue
Blue
White
Live:
Brown
Brown
Black
2.3.2.2
Protective Earth /Technical Earth
To achieve protection against earth faults in the installation, connected
to the equipment by signal cables etc., the equipment should always be
connected to protective earth. If the mains appliance coupler is
disconnected while signal cables are connected to the equipment, earth
Summary of Contents for SDI-IP-GTW
Page 1: ...network electronics com SDI to IP Gateway Rev 1 3 0 Flashlink User Manual SDI IP GTW...
Page 2: ...This page is intentionally left blank...
Page 4: ...SDI IP GTW User Manual 4 This page is intentionally left blank...
Page 8: ...SDI IP GTW User Manual 8 This page is intentionally left blank...
Page 56: ...SDI IP GTW User Manual 56 This page is intentionally left blank...
Page 61: ...SDI IP GTW User Manual 61 Figure 31 Data flow between two units...
Page 62: ...SDI IP GTW User Manual 62 This page is intentionally left blank...