background image

V0106Q  

Rev. 

 
 

 

8

 

 

General environmental requirements for Network Electronics 

equipment 

 

1.  The equipment will meet the guaranteed performance specification under the 

following environmental conditions: 

-  Operating room temperature range:  0°C to 45°C 

-  Operating relative humidity range: 

< 95% (non-condensing) 

 

2.  The equipment will operate without damage under the following environmental 

conditions: 

-  Temperature range: 

-10°C to 55°C 

-  Relative humidity range: 

< 95% (non-condensing) 

 

Summary of Contents for V0106Q

Page 1: ...network electronics com Analogue Video Distributor 1x6 Quad Rev 5 Flashlink User Manual V0106Q...

Page 2: ...this document is the uppermost in the table below Revision Replaces Date Change description 5 4 2007 10 29 New front page and removed old logo 4 3 2007 03 30 Added Materials Declaration and EFUP upda...

Page 3: ...5 2 3 Power connection 5 3 Connections 7 3 1 Termination of video signals 7 General environmental requirements for Network Electronics equipment 8 Product Warranty 9 Materials Declaration and EFUP 10...

Page 4: ...e enclosure Looped inputs allow forming of different configurations A high frequency 500MHz and high performance video amplifier circuit in SMD technology with minimum signal degradation makes the V01...

Page 5: ...3 Power connection Do not connect mains to the desktop power supply before connecting the power supply to the distributor Connect the DB9 female connector from the desktop power supply to the main un...

Page 6: ...V0106Q Rev 5 6 V0106Q requires 5V DC with a minimum current of 300mA The following pin out is used on the DB9 male power connector Pin 1 0V Pin 2 5V Pin 6 5V...

Page 7: ...of the V0106Q must always be terminated A 75 ohms termination plug is used direct on the V0106Q To assure correct frequency response a precision termination plug with 0 1 tolerance must be used If th...

Page 8: ...rformance specification under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range 95 non condensing 2 The equipment will operate witho...

Page 9: ...anty The warranty terms and conditions for the V0106Q follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Network Electronics ASA w...

Page 10: ...e Period EFUP EFUP is the time the product can be used in normal service life without leaking the hazardous materials We expect the normal use environment to be in an equipment room at controlled temp...

Page 11: ...on you require Where it is not possible to return the product to Network Electronics ASA or its agents for recycling the following general information may be of assistance Before attempting disassembl...

Page 12: ...EC HARMONISED STANDARDS applied in order to verify compliance with Directive s EN 55103 1 1996 EN 55103 2 1996 EN 60950 1 2006 TEST REPORTS ISSUED BY Notified Competent Body Report no Nemko 1999221570...