Product Warranty 

The warranty terms and conditions for the Modular SD/HD Video Router 
follow the General Sales Conditions by Network Electronics ASA. These 
conditions are available on the company web site of Network Electronics ASA: 
 

www.network-electronics.com 

Summary of Contents for VikinX HD128128M

Page 1: ...erer network electronics com VikinX Modular SD HD Video Router Rev 13 VikinX User Manual VD3232M VD6464M VD9696M VD128128M VD3232S VD6464S HD3232M HD6464M HD9696M HD128128M HD3232S HD6464S...

Page 2: ...EC Declaration of Conformity 11 10 Updated product names and GYDA section 10 9 08 02 06 Removed protocol and configuration details 9 8 28 09 05 Corrected RS 422 pinout description in Chapter 4 1 8 7 2...

Page 3: ...How to configure the router and modules 15 3 3 Power Supply module 16 3 3 1 Module insertion 16 3 3 2 Module removal 16 3 3 3 How to connect power to the Modular SD HD Video Router 16 3 3 4 Status LE...

Page 4: ...5 Connecting signal cables to the Modular SD HD Video Router 28 6 Before calling Network Support 29 7 Serial number overview 30 Notes 31 Materials Declaration and EFUP 32 Materials declaration 32 Env...

Page 5: ...ranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range 95 non condensing 2 The equipment will ope...

Page 6: ...ranty The warranty terms and conditions for the Modular SD HD Video Router follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Netw...

Page 7: ...censes The source code for these components and our modifications are available from http labs network electronics com open source You may also send Network Electronics a recordable CD and a self addr...

Page 8: ...control interfaces allowing the control of our routers through 3 rd party management software On top of that does the Network Electronics THOR management package allow control of the most common 3 rd...

Page 9: ...x96 HD128128M As above but fully equipped 128x128 High Definition Serial Digital Video 5RU HD3232S VikinX Modular multirateframe for SDI and HD SDI 19 4 to 1485 Mbps 5RU equipped 32x32 expandable up t...

Page 10: ...ly voltage range 36 72VDC 300W DC Mains connector Screw terminal separate input for each PSU module Alarms Power failure alarm on relay contact closure LED in front and Open Collector to GYDA VX Alarm...

Page 11: ...ndant Matrix Control using 2x SysCon TCP IP Web interface with GYDA VX SNMP agent With GYDA VX Event log With GYDA VX 2 4 Video specifications Supported formats Telecom STM 1 and E4 Broadcast 19 Mbps...

Page 12: ...ion both video formats Jitter 0 2 UI Reference inputs Number of inputs 2 standard both reference signals supplied to both SysCon when used in redundant mode Connector 75 ohm BNC female loop thru Retur...

Page 13: ...t DC DC PSU is installed screw terminals not mounted on illustrated router above Serial A1 and A2 RS 232 or RS 422 for external control protocols Serial B1 and B2 RS 232 or RS 422 for external control...

Page 14: ...VIT 1 Synchronisation signal 1 in out Blackburst composite tri level sync reference input with passive loop through for vertical interval switching VIT 2 Synchronisation signal 2 in out Blackburst co...

Page 15: ...nt The door may be removed for easy access to the modules An important feature of all the modules in the Modular SD HD Video Router frame is that they are all hot swappable The user does not have to t...

Page 16: ...ower supply module one must insert the module via the special plastic guide rails into its position Once the module is inserted fix the module by lifting up the handle on the front and pushing it to t...

Page 17: ...Ds on the front of each power supply module and they indicate the following The upper RED LED should be normally OFF If it is ON there is a power supply failure indicating that the power supply module...

Page 18: ...the SysCon card fails and install this CF card on a new SysCon card The router will not notice the difference 3 4 1 Card insertion The frame is equipped with plastic guide rails to align the SysCon c...

Page 19: ...release the card by moving the red handle until it is in horizontal position as shown in the figure below Then pull the card out of the sub rack with the red handle 3 4 3 Status LEDs and Reset button...

Page 20: ...t up and software reconfigurations upgrades Medium load on the Controller Low or normal load on the Controller Not applicable Reset button The reset button on the rear side is used to perform a hard r...

Page 21: ...to the description earlier in this manual 2 Slide the battery out of its socket and insert the new battery into the socket 3 Insert the SysCon card into its slot according to the description earlier...

Page 22: ...attery The Compact Flash CF card and battery are both inserted and or removed in the exact same way as on the SysCon card See Chapter 3 4 4 3 6 X point module Each VikinX Modular frame must be equippe...

Page 23: ...nwards the card The tip of the handles enters the hole and the card is locked and proper contact ensured when you hear a click from both handles 3 6 2 Card removal To remove an X point card from the f...

Page 24: ...ages on the card is outside their legal range All internal voltages are OK TEMP The temperature of the card is outside its legal range The temperature of the card is OK FAN1 Fan error when the fan spe...

Page 25: ...Modular SD HD Video Router Rev 13 25 switch must always be in the position towards the card front The switch is for factory use only Reset button Service switches SW4 SW2...

Page 26: ...mpact routers are as follows Bit rate 19200 bit s Data bits 8 bits Stop bits 1 Parity No parity For further detail concerning this protocol please refer to the following manual VikinX Compact Protocol...

Page 27: ...232 connection 4 3 Ethernet connection The connections follow the standard set by the IEEE 802 3 100BaseTX specification The cables that are to be applied should be CAT 5 CAT 5E standard or better It...

Page 28: ...uter Rev 13 28 5 Connecting signal cables to the Modular SD HD Video Router The Modular SD HD Video Router offers standard 75Ohms BNC connectors for video in and outputs All video inputs are terminate...

Page 29: ...d The Warn LED on the SysCon card is RED An abnormal situation has occurred See Chapter 2 If the router has redundant PSU modules check that both modules are properly installed and are working If the...

Page 30: ...numbers when contacting Network Electronics ASA for product support Device Part Part Serial number Frame including all static cards Power Supply Module 1 Power Supply Module 2 if included X point Card...

Page 31: ...Modular SD HD Video Router Rev 13 31 Notes...

Page 32: ...or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 Parts without any of the above mentioned hazardous sub...

Page 33: ...ur web site http www network electronics com Please contact Network Electronics ASA s Customer Support for assistance with recycling if this site does not show the information you require Where it is...

Page 34: ...quipment complies with LVD 73 23 EEC EMC 89 336 EEC HARMONISED STANDARDS applied in order to verify compliance with Directive s EN 55103 1 1996 EN 55103 2 1996 EN 60950 1 2006 TEST REPORTS ISSUED BY N...

Reviews: