5. MARK TEMPLATE "DOOR CONTACT SENSOR" HOLE
Mark the 3/4"
Door Contact Sensor
hole in the edge of the door for the correct door thickness.
Carefully remove the template.
6. MARK "DOOR CONTACT MAGNET" ON JAMB
The
Door Contact Magnet
must be installed in the door jamb such that when the door is closed, the
Door Contact Sen-
sor
is located
directly opposite
the
Magnet
. Install as follows:
6A.
Open the door and temporarily place a piece of tape across the center of the mark made for the
Door Contact
Sensor
in the previous step. This tape signifies the height (from the floor) of the
Door Contact Sensor
.
6B.
Close the door. Transfer this height to the door jamb with a light pencil mark.
6C.
Determine the center location on the jamb directly opposite the
Door Contact Sensor
when the door is closed.
Open the door and measure the distance from the door edge to the center of the
Door Contact Sensor
(0.875"
or
⅞
"). Transfer this distance to the door jamb, measured from the door stop.
FIG. 5: DOOR CONTACT SENSOR HOLE
ON DOOR EDGE
FIG. 5A: SELECT HOLE FOR DOOR THICKNESS
FIG. 6B: CLOSE DOOR AND
TRANSFER HEIGHT TO JAMB
FIG. 6A: TAPE SIGNIFIES
"HEIGHT FROM FLOOR"
FIG. 6C: LOCATE MAGNET IN JAMB
CENTERED DIRECTLY OPPOSITE THE
SENSOR WHEN DOOR IS CLOSED