Spate cleaner TANKO-SF
40/63
Translation of the original Operating / Installation Instructions 2016/09 Rev.1
7 Maintenance
For clip-on connection:
1.
Bend open the wire locking pin (5) Locking pin with the assembly/disassembly tool for the 2.4 mm
locking pin (Clipon) to one side.
2.
NOTE
The device could fall down!
The device could become damaged by impact effects.
When screwing out the parts, take care to ensure that the housing CAN NOT fall down
(e.g. by holding it with one hand).
Remove the wire locking pin (5).
3.
Detach the device from the pipe for the media supply.
For Weldon Connection:
To disassemble the welding version, the downpipe must be removed from the holder together
with the device.
Before removal, the downpipe [DP] is disconnected from the process connection [PC] and lifted out of
the container together with the device.
To perform maintenance on the device, all individual parts, except for the axle that is welded to the
downpipe, can be dismounted.
For permanent dismounting, the axle of the device can be separated from the downpipe with a suitable
procedure. The device will no longer be able to be used afterwards.
7.4
Maintenance
To ensure the trouble-free operation, high operational safety and long service life of the cleaning device,
it is imperative to have it cleaned and maintained at regular intervals.
We recommend that you document the maintenance work in a report.
Check and log the volumetric flow at regular intervals.
If the volumetric flow deviates by more than 15% from the values specified in these
instructions, then that is a sign of wear or blockage of the flow, and both the cleaning device
and the supply line must be checked. An inspection is recommended.
The safety notes in
section 7.1 Safety Notes for
must be adhered to when carrying out
cleaning, maintenance and repair work.