7 Maintenance
Maintenance Intervals and Methods
Shorten the maintenance intervals by 30% in the event of:
–
Deviation from the preferred installation position of the device
(see
section 5.2.2 Installation
–
Vibrations that occur in the plant which are NOT caused by the device and CANNOT be
prevented.
If the device is NOT operated for a longer period, we recommend that you check the device completely
before re-commissioning to make sure that it is fully functional
(see
section 6.2 Functional Check / Trial Run
The specified times of the maintenance intervals are based on single-shift operation
(8 hours per working day, 12 months per year) of the device
and operation with
Cleaning agent:
Water
Media pressure:
2 bar (29 psi)
Media temperature:
+25 °C (+77 °F)
Interval:
h
O
= operating hours of the device
Method:
V = visual inspection
F = functional check
M = measurement
C = cleaning*
*The cleaning intervals are to be defined by the operating company in accordance with operating
conditions.
Overview of Maintenance Points
A Axle (Media Connection [MC])
B Cage
C Nut
D O-ring
E Wire locking pin (only with Clipon)
Picture 7.4-1: Maintenance Points
B
D
C
A
E