background image

DETAILS

Change MIDI Channel

Replace “Channel # - 1” with the new MIDI Channel number minus 1. For example, 

to change the MIDI Channel number to 6, send the following bytes:

240, 0, 2, 40, 1, 1, 

5

, 247

Remap Control Change Number

Replace “Parameter #” with the Parameter Number in the Control Change table. 

Replace “CC #” with the desired Control Change number. For example, to change 

the Level parameter (

2

) to Control Change number 

7

, send the following bytes:

240, 0, 2, 40, 1, 2,

 2, 7

, 247

Preset Dump Request

This command requests all the preset parameters for a specified preset and 

will replace the normally-echoed THRU data from the MIDI OUT with the reply. 

Replace “Preset #” with the requested preset number. For example, to request 

Preset 6, send the following bytes:

240, 0, 2, 40, 1, 3, 

6

, 247

Summary of Contents for NEURON

Page 1: ...NEURON GAIN INTELLIGENCE...

Page 2: ...to earn your trust by delivering a quality product that inspires you to make great music Neunaber products are designed and manufactured in Orange California USA NEURON GAIN INTELLIGENCE USER GUIDE P...

Page 3: ...m for improvement or at least no room for unique greatness Each technological medium has strengths and weaknesses and to use one medium to emulate another denies its inherent power and versatility Sou...

Page 4: ...most hyper realistic when compared to an amplifier Among Neuron s many features are the following Integrated compressor constrains the drive level for smooth consistent tone Adjustable studio quality...

Page 5: ...CONNECTIONS Note Tilt EQ settings are a suggested starting point Adjust to taste Direct with Internal Speaker Simulator External Speaker Simulator...

Page 6: ...5 pin DIN are included clean channel input Tip The small speaker in a practice amp may sound more full range therefore try enabling the Speaker Simulator when running into the clean channel input or e...

Page 7: ...it is independent of the preset selection The Speaker Simulator filter is voiced to sound similar to Iconoclast with default settings and tone knobs at 12 o clock It is not adjustable Tilt EQ The glo...

Page 8: ...d level parameters of the compressor As such the compressor adds additional clean gain to your signal A moderate amount of compression can control the dynamics of your clean tones while a more modest...

Page 9: ...and release the switch Tightness The Tightness control adjusts a pre gain high pass filter Increasing this control will tighten the low end with high gain settings Increase the Low control to compens...

Page 10: ...see Saving Presets By default only one preset is accessible via the footswitch You may increase this to as many as 6 pressing the footswitch cycles through presets sequentially To access multiple pres...

Page 11: ...is preset may be changed whether in Manual Mode or in the preset itself The current settings are saved to preset 1 which then becomes active When multiple presets are accessible you must first recall...

Page 12: ...s Tilt EQ and Speaker Simulator selection Number of presets accessible via the footswitch A factory reset is initiated as follows Disconnect power Hold down the Engage switch Reconnect power Turn the...

Page 13: ...n the Engage switch and reconnect power Send any MIDI command containing the channel number to which to set Neuron Release the Engage switch Program Change Program Change numbers 0 24 are recognized 2...

Page 14: ...127 Mid 4 106 0 127 High 5 107 0 127 Low Pass Filter 6 108 0 127 Gate Threshold 7 109 0 127 High Pass Filter 8 110 0 127 Preset LED Color 9 111 0 red 1 blue 2 green 3 yellow 4 magenta 5 cyan Engage 10...

Page 15: ...ID number always 3 bytes 0 2 40 Device ID For Neuron always 1 EOX End of Exclusive always 247 Command Format SOX SysEx ID Device ID Command Number Data Bytes 1 11 bytes EOX Change MIDI Channel 240 0...

Page 16: ...ge table Replace CC with the desired Control Change number For example to change the Level parameter 2 to Control Change number 7 send the following bytes 240 0 2 40 1 2 2 7 247 Preset Dump Request Th...

Page 17: ...ransmitted to the MIDI IN to restore the preset Refer to the following Preset Write command for details Preset Write Replace Preset with the number of the preset you wish to overwrite Preset Data are...

Page 18: ...el MIDI IN OUT compliant with MIDI Specification CA 033 ELECTRICAL Sample rate 96 kHz Minimum latency 0 315 ms Bypass relay true bypass POWER Input 9 12 V DC Current 70 mA Connector center negative 5...

Page 19: ...o the State of California to cause cancer birth defects or other reproductive harm While we believe our products are not harmful when used as designed we provide this warning to comply with Propositio...

Page 20: ...www neunaber net...