NPPA-TT-SD50 Instruction Manual

Index 

 

1. Electrical configuration.................................................................................................3

 

2. Replacement of Jack Pairs ..........................................................................................4

 

3. Reconfiguration by hand..............................................................................................5

 

4. Grounding variations ...................................................................................................7

 

5. Wiring ..........................................................................................................................9

 

6. Cable retention to the unit..........................................................................................10

 

7. Channel identification ................................................................................................10

 

8. Technical data ...........................................................................................................12

 

9. Wiring Diagram..........................................................................................................13

 

10. Ordering Information................................................................................................14

 

 

 
 

Dimensional Drawing NPPA-TT-SD50 

 

 

 

Front panel 

 

Cable retention bar 

 

Top cover 

 

Summary of Contents for NPPA-TT-SD50

Page 1: ...983 811 441 Tel 1 732 901 9488 Tel 81 3 3663 4733 Tel 33 1 4131 6750 Tel 49 8131 28 08 90 Fax 423 232 53 93 Fax 41 44 736 5011 Fax 44 1983 811 439 Fax 1 732 901 9608 Fax 81 3 3663 4796 Fax 33 1 4131 0511 Fax 49 8131 28 08 30 www neutrik com Draft Nr BDA82 0 Update 16 01 2009 Data subject to change without prior notice 2007 NEUTRIK ALL RIGHTS RESERVED INSTRUCTION MANUAL NPPA TT SD50 PATCH PANEL Eas...

Page 2: ...cement of Jack Pairs 4 3 Reconfiguration by hand 5 4 Grounding variations 7 5 Wiring 9 6 Cable retention to the unit 10 7 Channel identification 10 8 Technical data 12 9 Wiring Diagram 13 10 Ordering Information 14 Dimensional Drawing NPPA TT SD50 Front panel Cable retention bar Top cover ...

Page 3: ...uilt to last The Neutrik Easy Patch is suitable for analog and digital audio signals The new generation of the Neutrik Easy Patch is easily programmable for any out of five electrical configurations half normalled bottom row half normalled top row full normalled parallel isolated The programming feature allows to set all possible switching configurations inside the jack pair with a specially desig...

Page 4: ...on air For replacement or re configuration just remove the easy accessible module consisting of two Plug in Units Module consisting of 2 Jack Pairs Remove Front Panel by unscrewing the 3 black cross recessed screws M3x8 Taptite remove the two side stops Push out the channel identification strips Pull one module out of the casing using the supplied disassembling pliers ...

Page 5: ... the left side of the jack pairs find their guiding slots If all jack pairs are removed start at the casing support in the center and assemble to the right and left side Slide in again the channel identification strips best from the outside inwards and fix the front panel with the black cross recessed screws Don t forget to insert the side stops before fixing the screws see page 10 3 Reconfigurati...

Page 6: ... small screw driver Insert new bars carefully by pressing them in parallel at both ends Attention To ensure best contact conditions never reuse the configuration bars once being put in place Always take new ones Keep the contacts and switches in place with the thumb while manipulating the normalling contacts Finally snap on the cover Insert it first at one side and then snap slightly into the oppo...

Page 7: ... The flexible grounding system provides the following alternatives to choose from Chassis Common All channel grounds top bottom row are connected via PCB and jumpers to the patch panel chassis as standard delivery configuration Sub D Group Central Ground contacts of top and bottom row are connected but separated from chassis Sub D Group Chassis Top or Bottom Either top or bottom ground contacts ar...

Page 8: ...ts from this device must be tied together This can be accomplished by grouping the grounds of these channels via the PCB bus using solder bridges This group is then connected onto the general technical ground Because of the missing SLEEVE normalling contact it is necessary to wire internally the ground sleeve contact of the top and bottom row of each channel If this is critical with respect to pos...

Page 9: ...T SD50 Instruction Manual 5 Wiring Four Sub D connectors with 50 pins each enable fast and easy wiring even with the patch panel installed in the rack Rear front for wiring 50 pin Sub D connector terminal SD50 Pin Header ...

Page 10: ...r For large and heavy bundles there is an additional strain relief bar NPPA S available It is attached to the casing with four screws Cable retention bar 7 Channel identification The front panel is equipped with channel identification strips located in the center of the channels and marked with the channel numbers 1 24 and 25 48 respectively Channel identification strips Labeling strips ...

Page 11: ... row To write on the paper you have to unscrew one of the outer fixing screws of the front panel Then pull out the side stop the transparent foil and the paper strip itself After marking is done assemble the parts in reversed sequence Remove labeling strip For easy and perfect marking you can use our designation software PatchLabel which is available on our web site www neutrik com free of charge ...

Page 12: ...istance 20 mΩ Switch contact resistance 25 mΩ Dielectric strength 1000 V dc 8 2 Mechanical Lifetime 5 000 Insertion withdrawal cycles Insertion Withdrawal force 10 N 8 N Cable retention force 70 N max per cable retention bar Dimensions rack mount 482 mm W 44 mm H 19 1 U Depth 178 mm 7 Weight 2 2 kg Temperature range 30 C to 80 C 8 3 Materials Jack housing PA 66 blend Jack contacts CuSn6 TRIBOR pla...

Page 13: ...Page 13 of 14 NPPA TT SD50 Instruction Manual 9 Wiring Diagram ...

Page 14: ...t bridges 5 contacts 96 Normal 2 medium bridges 6 contacts 48 Normal 3 long bridges 7 contacts 1 Disassembling pliers 1 Instruction Manual 10 2 Options and Accessories Order Information for Pre configured jack pairs and Accessories NJ3TTA 4 HNB blocks of 2 channels half normalled bottom row cover identification color clear NJ3TTA 4 HNT blocks of 2 channels half normalled top row cover identificati...