background image

G

opticalCON

After  the  cleaning  procedure  unlock  the  NEUTRIK 
inspection tool (G).

Wet cleaning using lint-free wipes

Press  forward  the  twist  prevention  and  untight  the 
connector bushing and remove carefully the insert of
the connector housing.

Inspect the LC connectors with a video probe tool.

Fold a lint free wipe into a square with one drop of 
cleaning  fluid.  Be  sure  that  a  portion  of  the  wipe 
remains dry.

Wipe  slightly  the  ferrule  tip  in  the  cleaning  fluid 
moistened portion of the wipe. Immediately repeat 
this wiping action on the dry section of the wipe to 
remove any residual alcohol.

Dispose the wipe. NEVER REUSE A WIPE.

Inspect the connector again with a video probe tool.

Repeat the process if necessary.

After  the  cleaning  procedure  slide  the  connector 
insert back into the connector housing. Align the key 
on the insert to the cutout of the metal housing.

Screw both connector parts togehter.

 1.9

2.

2.1

2.2

2.3

2.4

2.5

2.6

2.7

2.8

2.9

  

I  

HANDLING INSTRUCTION

®

optical

CON

 DUO

4

BDA 520

cleaning fluid

FOCD-CF

FOCD-DW

Summary of Contents for opticalCON DUO

Page 1: ...HANDLING INSTRUCTION opticalCON DUO Maintenance R R www neutrik com BDA 520 ...

Page 2: ...orrelate tip C Under the following QR code you can find a list with ThesealingshuttermechanismoftheopticalCON avoidscontaminationoftheLCferrulelockedinside The dust proof design reduces maintenance intervals to a minimum if nevertheless necessary follows the maintenance procedure below to avoid damages on the due to inpropes cleaning 2 C 1 1 1 1 2 1 3 optical fiber Microscope B Service tool FOCD S...

Page 3: ... D To inspect the LC ferrule surface focus the video probe by rotating the focus wheel E Clean the LC surface with the Dry Cleaner 1 25 mm over the NEUTRIK DUO service tool Push back and forth the dry cleaner to start the cleaning procedure F An endless lint free tape removes dust particle on the ferrule surface of the LC connector Check the condition of the LC ferrule surface again and if necessa...

Page 4: ...Wipe slightly the ferrule tip in the cleaning fluid moistened portion of the wipe Immediately repeat this wiping action on the dry section of the wipe to remove any residual alcohol Dispose the wipe NEVER REUSEAWIPE Inspect the connector again with a video probe tool Repeat the process if necessary After the cleaning procedure slide the connector insert back into the connector housing Align the ke...

Page 5: ...again with a video probe tool Repeat the process if necessary 1 1 1 1 2 1 3 1 4 2 2 1 2 2 2 3 2 4 2 5 2 6 BA N E UT IK R Dry Cleaner FOCD DC125 Tools Ÿ Dry Cleaner 1 25 mm FOCD DC125 Ÿ 99 isopropyl alcohol IPA or cleaning fluid FOCD CF Ÿ Lint free wipes FOCD DW Ÿ Video probe CAS FOCD 1 1 1 2 Draft Nr BDA 520 V2 Update 2020 01 07 I www neutrik com Neutrik AG LI T 423 237 24 24 F 423 232 53 93 Neutr...