33
12. Troubleshooting
Before requesting repairs, refer to the following table. Consult your New Cosmos
representative if the product does not return to normal after taking the corresponding remedies
shown below or if the defective condition is not found in the table.
If the product goes into an unintended mode at the adjustment or setting stage, stop operating
the product immediately and consult the system administrator.
Defective condition
Probable cause
Remedy
Reference page
The green power lamp is
not lit.
Incorrect wiring
connection.
Check and redo the
wiring.
P. 12
Wiring and
Connection
The yellow lamp to
indicate an error is flashed
and the error code is
displayed.
Low-voltage state
Check the power supply
voltage.
The sensor unit is
defective, the connector
is disconnected, or the
sensor wires are broken.
Check that the sensor
connector is connected
securely.
P. 12
Wiring and
Connection
If there is a possibility
that the sensor is
defective or sensor
wires are broken,
contact your local
representative.
The detected gas
concentration and
are flashing
alternately.
The product is in
maintenance mode.
Return the product to
gas monitor mode.
P. 25
Maintenance
Mode
There is no alarm contact
output.
The product is in
maintenance mode.
Return the product to
gas monitor mode.
P. 25
Maintenance
mode
Incorrect wiring
connection.
Check and reconnect the
wiring.
P. 12
Wiring and
Connection
The alarm point setting
is wrong.
Check the alarm setting.
P. 29
Full-scale and
Alarm Set Display
The analog signal does
not change
The product is in test
mode.
Return the product to
gas monitor mode
P. 30
Test mode
A value and
are flashing alternately.
The sensor output is
high.
The concentration of gas
is in excess of the full
scale. Check the
ambient environment.
A value and
are
flashing alternately.
The sensor output is low.
Conduct zero
adjustment after
checking that the air
around the product is not
contaminated with gas.
P. 26
Zero adjustment
No adjustment or setting is
possible.
The product is operated
during the initial delay
time.
Operate the product
after the 30-second
initial delay time.
P
. 18
Display at Start-up
(Initial Delay)
Summary of Contents for KD-12B