SECTION 8 -- SPECIFICATIONS
8--10
COOLING SYSTEM
T6010
T6020
T6030
T6050
T6070
Type
Pressurised, with full flow bypass and recovery tank
Cooling fan, number of blades
Fixed drive
5
5
5
5
5
Viscous drive
5
5
5
5
5
Diameter
mm
510
510
510
510
510
in.
20.0
20.0
20.0
20.0
20.0
Thermostat
Begins to open at:
°
C
81
81
81
81
81
°
F
178
178
178
178
178
Fully open at:
°
C
96
96
96
96
96
°
F
205
205
205
205
205
Radiator pressure cap
bar
1.0
1.0
1.0
1.0
1.0
lbf.in
2
14.5
14.5
14.5
14.5
14.5
TRANSMISSION
Synchro Command
12x12
30 km/h
30 km/h
30 km/h
30 km/h
--
Dual Command
24x24
30 km/h
30 km/h
30 km/h
30 km/h
30 km/h
24x24
*
40 km/h
*
40 km/h
*
40 km/h
*
40 km/h
*
40 km/h
Electro Command
16x16
30 km/h
30 km/h
30 km/h
30 km/h
30 km/h
16x16
*
40 km/h
*
40 km/h
*
40 km/h
*
40 km/h
*
40 km/h
17x16
*
50 km/h
*
50 km/h
*
50 km/h
*
50 km/h
*
50 km/h
*
4WD tractors only
Clutch type -- 12x12
mm
330
330
355
355
--
Dry, ceremetallic -- diameter
in.
13.0
13.0
14.0
14.0
--
Clutch type -- 24x24
Oil immersed disc, No. of plates
6 friction 6 steel plates
Clutch type -- 16x16 (17x16)
Oil immersed disc, No. of plates
4 friction 4 steel plates
Creeper Gear Operation
12x12 transmission
Lever
Lever
Lever
Lever
--
24x24 and 16x16 transmission
Switch
Switch
Switch
Switch
Switch
Summary of Contents for T6010 DELTA
Page 1: ...OPERATOR S MANUAL T6010 T6020 T6030 T6050 T6070 Delta and Plus Tractors ...
Page 6: ...BLANK ...
Page 28: ...SECTION 1 GENERAL INFORMATION AND SAFETY 1 22 NOTES ...
Page 280: ...SECTION 3 FIELD OPERATION 3 146 NOTES ...
Page 366: ...SECTION 5 FAULT FINDING 5 12 NOTES ...
Page 368: ...SECTION 6 VEHICLE STORAGE 6 2 NOTES ...
Page 400: ...SECTION 8 SPECIFICATIONS 8 24 NOTES ...
Page 402: ...SECTION 9 1ST 50 HOUR SERVICE SHEETS 9 2 ...
Page 404: ...SECTION 9 1ST 50 HOUR SERVICE SHEETS 9 4 ...
Page 410: ...SECTION 10 INDEX 10 6 ...
Page 412: ...sblank ...