SECTION 2 -- CONTROLS, INSTRUMENTS AND OPERATION
2--51
Calibrating the Ground Speed Display
Should you wish to install alternative rear tyre
equipment that would provide a radius difference of
more than 13 mm (0.5 in), then the electronic control
module should be re--calibrated to display an
accurate ground speed figure. To re--calibrate use
one of the following methods:
IMPORTANT:
If your tractor is equipped with the
optional slip control feature, then the ground speed
displayed is a true speed as sensed by a radar unit,
calibration is therefore
not
required.
•
Ensure that the tyre pressures are correct for the
load being carried. (See Tyre Load/Inflation
tables in Section 3 of this manual).
•
Select a stretch of dry, firm, level ground
(preferably concrete) and carefully measure out
a distance of exactly 100.0 m (328 feet). Mark the
start and finish of this measured distance with a
bold chalk line.
Auto Calibration with CAL/SEL Button
•
Park the tractor a short distance from the start
line and, with the engine running, depress and
hold the CAL/SEL button for 3 seconds to enter
the calibration mode.
SETUP_MENU
will appear
in the Dot Matrix Display. After approximately
two seconds the display will change to
CAL
.
Depress the CAL/SEL button again to enter the
calibration mode. Using the clock Hour button
select
CAL auto.
Depress the CAL/SEL button
to confirm selection of
CAL auto
, the central
LCD display will read
0000.
NOTE:
The set up procedure may be cancelled at
any time by depressing the LCD dimmer control
button or by turning the key--start off.
92
•
Select a suitable transmission ratio to provide a
speed above 3 km/h (1.8 MPH) and drive up to
the start line,
CAL auto READY
will appear in the
display. As the centre of the front tyres passes
over the start line, press and release the
CAL/SEL button.
CAL
will flash in the speed
display,
CAL auto ON
will appear in the DMD and
the central LCD will show a four digit figure that will
increase as the tractor moves forward.
NOTE:
If the calibration procedure is incorrectly
performed i.e. speed below 3 Km/h (1.8 MPH),
CAL
KO
will appear in the display, depress CAL/SEL to
restart sequence.
93
Summary of Contents for T6010 DELTA
Page 1: ...OPERATOR S MANUAL T6010 T6020 T6030 T6050 T6070 Delta and Plus Tractors ...
Page 6: ...BLANK ...
Page 28: ...SECTION 1 GENERAL INFORMATION AND SAFETY 1 22 NOTES ...
Page 280: ...SECTION 3 FIELD OPERATION 3 146 NOTES ...
Page 366: ...SECTION 5 FAULT FINDING 5 12 NOTES ...
Page 368: ...SECTION 6 VEHICLE STORAGE 6 2 NOTES ...
Page 400: ...SECTION 8 SPECIFICATIONS 8 24 NOTES ...
Page 402: ...SECTION 9 1ST 50 HOUR SERVICE SHEETS 9 2 ...
Page 404: ...SECTION 9 1ST 50 HOUR SERVICE SHEETS 9 4 ...
Page 410: ...SECTION 10 INDEX 10 6 ...
Page 412: ...sblank ...