- 43 -
L5034G4
www.NewLeader.com
(800) 363-1771
305438-J
Conveyor Gearcase
Exposure to lubricant grease and oil, or hydraulic oil can cause personal injury. Do not allow
these products to remain in contact with the skin or eyes� Ingestion of these products or
inhalation of fumes from these products can cause dizziness, nausea, vomiting, or poisoning�
If exposure to any of these products occurs, or if any of these products are ingested or if
fumes are inhaled, please consult the product’s SDS for proper first aid or medical procedures.
Failure to comply with this requirement could result in death or serious injury�
Drain oil in a new unit after first two weeks (or not more than 100 hours) of operation, and flush gear case
thoroughly with light oil. Refer to “Lubricant and Hydraulic Oil Specifications” section for proper grade oil
and recommended amounts of lubricant� After initial change, oil should be changed every 2,000 hours of
operation or annually, whichever occurs first. Check gearcase oil level monthly.
Bin Sensor
Stay out of the spreader� Do not climb on spreader� Use a portable ladder to inspect, clean
and maintain the bin sensor from outside the spreader� Failure to do so could result in injury
from falling�
Wipe sensor clean periodically to prevent accumulation of product� Avoid wet material as it
may stick to sensor� If material sticks to sensor it won’t warn user when bin is low�
Clean sensor with long handled brush or hose from outside of spreader� Do not aim high pressure sprayer
directly at sensor—it could damage the components�
Lubrication of Bearings
Grease in a bearing acts to prevent excessive wear of parts, protects ball races, and balls from corrosion
and aids in preventing excessive heat within the bearing. It is very important the grease maintain its proper
consistency during operation. It must not be fluid and it must not channel.
Make sure all fittings are thoroughly cleaned before grease is injected. Points to be lubricated by means of a
grease gun have standard grease fittings. Lubricate bearings by pumping grease slowly until it forms a slight
bead around the seals� This bead indicates adequate lubrication and also provides additional protection
against the entrance of dirt�
Fasteners
Tighten all screws fasteners to recommended torques after first week of operation and annually thereafter.
If loose fasteners are found at anytime, tighten to recommended torque� Replace any lost or damaged
fasteners or other parts immediately� Check body mounting hardware every week�
Clean-Up
High pressure wash can inject water and/or fertilizer into control components, causing
damage� Use caution when cleaning these areas�
Thoroughly wash unit every two to three days during the operating season to maintain minimal maintenance
operation� Hose unit down under pressure to free all sticky and frozen material�
It is important the unit be thoroughly cleaned at the end of each operating season� All lubrication and
maintenance instructions should be closely followed� Repaint worn spots to prevent formation of rust�
Lubrication & Maintenance
Summary of Contents for L5034 G4
Page 6: ...Insert Current New Leader Warranty Warranty...
Page 7: ...SAFETY...
Page 26: ...INSTALLATION...
Page 35: ...33 This page is intentionally left blank L5034G4 www NewLeader com 800 363 1771 305438 J Notes...
Page 36: ...34 This page is intentionally left blank www NewLeader com 800 363 1771 305438 J L5034G4 Notes...
Page 37: ...OPERATIONS MAINTENANCE...
Page 50: ...47 L5034G4 www NewLeader com 800 363 1771 305438 J Troubleshooting Hydraulic Schematic...
Page 54: ...CONTROLLER...
Page 91: ...SPREAD PATTERN...
Page 102: ...PARTS...
Page 114: ...108 www NewLeader com 800 363 1771 305438 J L5034G4 Main Bin Body Hydraulics...
Page 115: ...109 L5034G4 www NewLeader com 800 363 1771 305438 J Main Bin Cont Body Hydraulics...