- 104 -
www.NewLeader.com
(800) 363-1771
307306-AA-D
NL450C
Header
• Using the control buttons
(Reset,
Run, Stop), run a catch test. If spreading product
that has already been tested, press
to
continue. To begin a test, press
. Conveyor will
run.
• Once controller dispenses speci
fi
c amount,
conveyor will stop. Press
to continue.
• Weigh material dispensed and enter actual weight
of material dispensed. Press
to continue.
• It is recommended a minimum of three (3) tests be
done PER PRODUCT to ensure accuracy. Once
each test is done, press “Repeat Calibration” to
run a subsequent test. When
fi
nished, press
.
• The main Calibration screen will appear. To
calibrate with a known amount brought to a
fi
eld,
press
.
Note:
Field totals can be reset from Summary
Screen if needed.
Controller Operations