8) Using the special knob (See picture 3A), insert the filter cartridge into the slot of the waste settling chamber (See picture 3B).

9) Make sure that the filter bag is facing the aquarium and that it comes out of the NEWA Pgr gravel cleaner unit (See picture 4).

10) Completely assemble the aspiration unit, checking that the hoses perfectly fit into the hose fittings.

11) Immerse the hard aspiration pipe into the aquarium as far as the bottom and insert the flexible hose connector into the aspiration unit 

housing (See picture 5). 

12) Pour water from the aquarium into the waste aspiration unit until it is half full (3-4 glasses according to the PGR model).

The water must cover the impeller chamber (See picture 6).

13) Then connect the power supply, and the vacuum cleaner starts automatically. NEWA Pgr gravel cleaner  is ready for use. 

ADVICE FOR USE

The vacuum cleaner NEWA Pgr gravel cleaner has considerable power, and so is ideal for every kind of aquarium.

It is also provided with a strainer which ensures that gravel and small fishes can not reach the suction pump.

Always remember to attach the protection grid (See picture 7).

For the most efficient use of the cleaner read the following advice:

1) Introduce the end of the vacuum pipe into the gravel at least 2-3 cm.

2) Move the vacuum sideways and up and down in order to disturb the gravel and make suction of sediment easier.

3) Avoid suction of coarse pieces of dirt or leaves which could clog the strainer.

4) When the water level inside the filter box rises above the filter cartridge, this means that the filter bag is blocked and must be rinsed 

under running water.

CLEANING AND MAINTENANCE

Filter box:

 the filter box does not require particular cleaning procedures. Do not use soap or other kind of detergent: any residual is 

potentially harmful to the chemical balance of the aquarium. Use only warm water and a soft cloth.

Impeller chamber:

 lift and take off the impeller chamber as shown in picture 8. The magnetic rotor and the impeller will be visible because 

they are attached to the impeller chamber. If necessary it is possible to clean the impeller, the rotor and the impeller chamber.

Important: if any stones or sand should enter the impeller chamber, the impeller might become blocked. It is advisable, in 

this case, to clean the motor, carefully following the instructions.

Motor:

 under normal circumstances it is not necessary to remove the motor; if however it is necessary:

1) Hold the filter box in one hand and the motor with the other (See picture 9A).

2) Move the motor 90° in anti-clockwise direction (1/4 turn) until the motor is set parallel to filter box. Section b of picture 9 shows the 

position of the motor after 1/4 turn.

3) Holding the filter box remove the motor (See picture 9C).

4) Clean the internal part of the motor and the o-ring only using cotton. Do not use any  kind of metal tool: it could damage the motor. Clean 

with vinegar if limestone is present.

NOTE: CHECK THAT THE O-RING DOES NOT HAVE CUTS OR CRACKS -REPLACE THE O-RING IF DAMAGED.

5) Assemble the motor and slightly wet the o-ring before connecting it to the filter box. Check for leaks in the filter box before use.

Suction set:

 wash under running water after use. Do not use chemical detergents or soap.

GUARANTEE

This product is guaranteed, in compliance to European directive 1999/44 EC, as free from faults both in materials and workmanship for a 

period of 24 months from date of purchase. If the product fails to operate correctly within the first two years of the date of purchase, return 

it to the retailer where it was purchased. The product shall be replaced free of charge

During the period of warranty the product shall be replaced if:

1) The product is returned carefully packaged and has not been damaged in transport.

2) Proof of purchase is supplied along with a detailed explanation of reasons for the claim.

The warranty is subject to the following restrictions and conditions:

1) The warranty does not cover accidental damage or breakage.

2) Replacement of the product in no way represents admission of responsibility.

3) The warranty is not  valid in the case of improper use, and does not cover damage caused by tampering or negligence on the part of the 

purchaser.

4) The warranty is not valid for components subjected to wear (*).

KEEP THESE INSTRUCTIONS

7

Summary of Contents for 8017003074411

Page 1: ...BLE D AQUARIUM Mode d emploi et Garantie BODENREINIGER F R AQUARIEN Gebrauchsanleitung und Garantie AQUARIUMGRIND REINIGINGSSET Aanwunzingen Garantie ASPIRADOR PARA LA LIMPIEZA DEL FONDO DE LOS ACUARI...

Page 2: ...PGR MODELS WATT Q L h FOR AQUARIUMS 1000 5 W 220 240V 50Hz 340 L h max 120 l 2000 6 W 650 L h max 500 l 2...

Page 3: ...Fig 1 Fig 2 Fig 3A Fig 3B Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 water level A OK B 90 C 3...

Page 4: ...anneggiato sostituire l intero apparecchio 4 Controllare che il voltaggio stampato sul motore dell aspirarifiuti corrisponda a quello della rete di alimentazione 5 Sel apparecchiocadeinacquanoncercare...

Page 5: ...morbido Camera della girante sollevare ed estrarre la camera della girante come indicato in fig 8 Il rotore magnetico e la girante saranno visibili in quanto attaccati alla camera della girante Se ne...

Page 6: ...ildrenwithoutsupervision 2 WARNING turn off and disconnect all the electrical equipment in the aquarium before carrying out any maintenancetasks 3 Thepowercordmustnotberepairedorreplaced Ifitisdamaged...

Page 7: ...ber If necessary it is possible to clean the impeller the rotor and the impeller chamber Important if any stones or sand should enter the impeller chamber the impeller might become blocked It is advis...

Page 8: ...es dangers li s son utilisation Les enfants ne doivent pas jouer avec l appareil parce que ce n est pas un jouet Lesop rationsdenettoyageetd entretienincombant l utilisateurnedoiventpas treeffectu esp...

Page 9: ...r sur la figure 8 Le rotor magn tique et la turbine seront visibles car ils sont rattach s la chambre de la turbine En cas de n cessit il est possible de nettoyer la turbine le rotor et la chambre de...

Page 10: ...t mit dem Ger t spielen daeskeinSpielzeugist DievomBenutzerdurchzuf hrendeReinigungundWartungdesGer tsdarf nichtvonunbeaufsichtigtenKinderndurchgef hrtwerden 2 ACHTUNG vor Installations und Instandhal...

Page 11: ...8 Der magnetische Rotor und die Turbine werden sichtbar weil diese an der Turbinenkammer befestigt sind Im Notfall ist es m glich die Turbine den Rotor und die Turbinenkammer zu reinigen Achtung wenn...

Page 12: ...diedoordegebruikermoetenwordenverricht mogennietdoor kinderenzondertoezichtgedaanworden 2 LET OP ontkoppel alle electrische toepassingen in het aquarium voordat u installatie en onderhoudswerkzaamhede...

Page 13: ...ere reinigingen onderworpen te worden Gebruik geen zeep of andere reinigingsmiddelen omdat deze zeepresten kunnen achterlaten die schadelijk zouden kunnen zijn voor het chemische evenwicht van het aqu...

Page 14: ...ia de la humedad en el enchufe o toma de corriente el ctrica desconecteelinterruptorprincipalantesdedesconectarelcabledealimentaci n 3 Elcabledealimentaci nnopuedeserreparadoocambiado Siest da ado sus...

Page 15: ...que podr an dejar residuos que podr an perjudicar el equilibrio qu mico del acuario Usar s lo agua caliente del grifo y un pa o suave C mara del rodete levantar y extraer la c mara del rodete como se...

Page 16: ...semsupervis o 2 ATEN O Desligar todos os aparelhos el ctricos que est o no aqu rio antes de come ar a instala o e manuten o Caso esteja algum l quido na tomada ou conector desligar a chave geral ante...

Page 17: ...ro detergente pois que esses podem deixar res duos que podem ser prejudiciais para o equil brio qu mico do aqu rio Usar apenas gua quente da torneira e um pano macio C mara do impulsor levantar e extr...

Page 18: ...NEWA Pgr gravel cleaner NEWAPgrgravelcleaner NEWA Pgr gravel cleaner EN 60335 2 41 1 8 2 3 4 5 6 4 1 7 8 9 10 35 C 11 12 13 Idn 30 NEWA Pgr gravel cleaner 1 2 2 PGR 3 4 NEWA Pgr gravel cleaner RU 18...

Page 19: ...5 6 7 8 3A 3B 9 PGR 4 10 11 5 12 3 4 PGR 6 13 NEWA Pgr gravel cleaner NEWA Pgr gravel cleaner 7 1 2 3 2 3 4 8 1 9A 2 90 1 4 9 1 4 3 9C 4 5 1 3 6 1999 44 CE 24 1 2 1 2 3 4 19...

Page 20: ...EWA Pgr gravel cleaner NEWA Pgr gravel cleaner NEWA Pgr gravel cleaner EN 60335 2 41 1 8 s 2 3 4 5 6 1 7 8 9 10 35 C 11 12 13 Idn 30 mA NEWA Pgr gravel cleaner 1 2 2 PGR 3 4 NEWA Pgr gravel cleaner 5...

Page 21: ...7 8 3A 3B 9 PGR 4 10 11 5 12 3 4 PGR 6 13 NEWAPgrgravelcleaner NEWA Pgr gravel cleaner 7 1 2 3 2 3 4 8 1 9A 2 90 1 4 B 9 1 4 3 9C 4 O Ring O Ring 5 O Ring 1 3 6 1999 44 CE 24 1 2 1 2 3 4 21...

Page 22: ...ny za zen v akv rium nebo z sobniku 3 Zkontrolovat zda nap jec kabel p slu enstv je po kozen Ten kabel ne podleh je oprav nebo v m n Pripo ko en kabelujenutn v m nitcel za zen 4 Zkontrolujte zda nap t...

Page 23: ...e a vyjm te komoru ob n ho kola dle uk zky na obr 8 Magnetick rotor a ob n kolo budou viditeln nebo jsou p ipojeny ke komo e ob n ho kola V p pad pot eby bude mo n vy istit rotor ob n kolo a komoru ob...

Page 24: ...en mus tevymeni cel zariadenie 4 Skontrolujte i daj o nap t vytla en na motore odkalova a zodpoved nap tiu nap jacej siete 5 Akzariadeniespadnedovody nesna tesahovybra rukou napriektomu emotorjeperfek...

Page 25: ...zornenie v pr pade ak by sa do komory obe n ho kolesa dostali kamienky alebo piesok obe n koleso by sa mohlo zablokova Iba v tomto pr pade sa odpor a vykona istenie motora pri om je potrebn starostliv...

Page 26: ...avel cleaner NEWA Pgr gravel cleaner NEWA Pgr gravel cleaner UE EN 60335 2 41 1 2 3 4 1 5 6 7 8 35 C 9 10 11 30 RCD 12 13 NEWA Pgr gravel cleaner 1 2 2 NEWA Pgr gravel cleaner 3 4 NEWA Pgr gravel clea...

Page 27: ...8 3A 3B 9 NEWA Pgr gravel cleaner 4 10 11 5 12 PGR 3 4 6 13 NEWA Pgr gravel cleaner NEWA Pgr gravel cleaner 7 1 2 3 2 3 4 8 1 9A 2 90 1 4 9B 1 4 3 9C 4 O O 5 O 1 3 6 1999 44CE 24 1 2 1 2 3 4 27...

Page 28: ...28...

Page 29: ...29...

Page 30: ...heteinde van zijn gebruiksduur Om mogelijke schade aan het milieu of de menselijke gezondheid door ongecontroleerde afvalverwijdering te voorkomen moet u dit product van andere soorten afval scheiden...

Page 31: ...ZUBEH R RECAMBIOS Y ACCESORIOS PARTI DI RICAMBIO E ACCESSORI RU BG RAEE 01 02 03 04 05 06 07 01 02 03 04 05 06 Nr PGR 1000 PGR 2000 07 00 60 015 00 60 016 00 60 017 00 54 020 00 53 023 00 60 018 00 6...

Page 32: ...tigianato 2 35010 Loreggia PD Tel 39 049 5794069 Fax 39 049 5794699 NumeroVerde 800 860306 www newa it CHINA NEWA ELECTRICAL SUZHOU CO Ltd 3rd Floor Block 2 NO 22 ofYinsheng Road ShengPu Suzhou Indust...

Reviews:

Related manuals for 8017003074411