EN
www.newair.com
25
Problem
Possible Causes
Solution
The humidor
produces a lot of
noise.
The unit is not leveled.
See above.
Check the fan.
Check the fan to make
sure there is no debris or
obstruction. If not, contact
the Newair Customer
Support Department.
Left window
shows HH
“High
Temperature”
.
Ambient temperature is
too high.
Avoid using at ambient
temperature above 108
degrees Fahrenheit.
Leakage in refrigeration
system or failure of
indoor fan.
Contact a qualified
technician for repairing.
Left window
shows LL
“Low
Temperature”
.
Ambient temperature is
too low.
Avoid using at ambient
temperature below 32
degrees Fahrenheit.
Refrigeration system
failure.
Contact a qualified
technician for repairing.
Right window
shows HH
“High
Humidity”
.
Appliance is in a high
humidity environment
and shows higher than
set humidity by 15% for
more than 48 hrs.
If there is water in the
water box it must be
drained at this time.
Refrigeration system
failure.
Contact a qualified
technician for repairing.
Right window
shows LL
“Low
Humidity”
.
Humidity is lower than
set humidity by 15% for
more than 48 hrs. There
might be no water in the
water box.
Add water to the water
box.
Refrigeration system
failure.
Contact a qualified
technician for repairing.