EN
www.newair.com
14
OPERATING INSTRUCTIONS
1.
Temperature increase and defrost on/off button (this button will only
adjust the temperature if the temperature adjustment button is selected
first. Otherwise, it will change the defrost setting.) Press and hold this
button for 6 seconds to manually enable/disable defrosting mode.
2.
“
Cooling
Active”
indicator light (indicates that the compressor is running)
3.
“
Defrost
Active”
indicator light. The unit defrosts automatically in normal
operating conditions. The evaporator behind the rear wall of the unit
defrosts automatically. The condenser connects in the drainage channel
behind the rear wall of the unit and flows through the drainage hole into
the drip tray by the compressor where it evaporates. However, frost may
accumulate on the evaporator if the unit is repeatedly opened in a high
heat or high humidity location. If this frost pattern does not clear within 24
hours, your unit will require manual defrosting. Press and hold for 6
seconds, the unit will be defrosted. To stop defrost, press again.
4.
“Lights On”
indicator light
5.
Power button (press and hold to turn the unit on or off without having to
unplug the power cord)
6.
°F and °C switch icon (press and hold both buttons to change from F to C)
7.
Temperature adjustment button (press once to adjust temperature). Once
your temperature is selected, the display will flash the selected
temperature for 5 seconds, then revert back to displaying the ambient
temperature. To view the set temperature at any time, press the key. The
set temperature will flash in the display window for 6 seconds. After 6
seconds, the temperature inside the unit will reappear in the display
window. (The temperature preset at the factory is 32°F).