Setting Up The Unit
18
Legend Setup
Please refer to Page 10, Legend Setup
Setup Axis 4 (Digital Linear)
For models with 5v TTL quadrature 4th axis
Encoder Setup
To select
Linear
as the encoder type
Display Resolution
Enter the resolution that is required to be displayed using the numerical keys.
The displayed resolution can only be the same or higher than the encoder resolution.
Example:
Linear Encoder has a resolution of 1µm (0.001) and is to be displayed at 5µm (0.005).
Navigate to
Note:
Inch / mm function must be set to reflect entered resolution
Encoder Resolution
Enter the resolution of the encoder for the 4th digital axis using the numerical keys.
It is important the resolution of the encoder is entered exactly or inaccurate measurements will occur.
Example:
Linear encoder has a resolution of 0.001mm.
Navigate to
Note:
Inch / mm function must be set to reflect entered resolution
Reference Source Setup
To select
Internal
referencing
To select
External
referencing
The DP1200 is capable of using an internal reference or an external reference source for the digital 4th
axis. An internal reference is the reference mark provided by the encoder.