Setting Up The Unit
Encoder Setup
20
Legend Setup
Setup Axis 4 (Digital Rotary Angular)
For models with 5v TTL quadrature 4th axis. The rotary angular option is for customers using
a rotary encoder who want an angular displayed measurement
Please refer to Page 10, Legend Setup
To select
Rotary
(
Angular
) as the encoder type
Encoder Resolution Setup
To select
Program Resolution
To select
Teach Resolution
Program Resolution Setup
Teach Resolution Setup
This setting allows the user to program the DP1200 with a rotary encoder resolution.
Rotary encoder resolutions are usually expressed as
Pulses Per Turn
. This is the number of pulses
output per revolution.
Information on the
PPT
can be found in the encoder manufacturer’s specification and is also generally
marked on the encoder.
Navigate to
Example
Rotary encoder has a
PPT
of 1024
Reference Source Setup
Please refer to Page 16, Reference Source Setup
Rotate rotary encoder until a value
is displayed in the LCD
display.
For this example an 1800 pulse
encoder is connected.
PPT = Counts per Revolution (CPR) /4
Summary of Contents for dp1200
Page 1: ...User Manual DP1200 Digital Readout...
Page 2: ......