EU Directive 73/23/EEC (Low Voltage Directive)
BS EN 55022:1998 Class B
BS EN 55024:1998
Input to Power Supply Unit (Supplied)
100-240V (47-63Hz)
External switch-mode - Output voltage 15VDC
Input Voltage to DP1200 15-24VDC ±10%
Conforms to Low Voltage Directive
Height
215mm (8 ½")
Depth
68mm (2 ¾")
Width
310mm (12 ¼")
Weight
3.5kg (7 ¾lb)
Climatic Range
Storage Temperature
-20°C (-4°F) to 70°C (158°F)
Working Temperature
-10°C (14°F) to 50°C (122°F)
Working Humidity
95% R.H. at 31°C (87.8°F)
IP-Ingress Protection
IP54 Panel Mount
IP40 Stand Alone
At the end of its life, you should dispose of the DP1200 system in a safe manner applicable to
electrical goods
Do not burn
The casework is suitable for recycling. Please consult local regulations on disposal of electrical
equipment
Encoder inputs 1, 2 & 3 can be used with Spherosyn 2G and Microsyn 2G analogue encoders.
Encoder input 4 can be used with Spherosyn 2G / Microsyn 2G or 5v TTL Quadrature, depending on
the model ordered.
Note:
It is possible to upgrade the DP1200 from a 2 or 3 Axis up to 4 Axes, See Page 26 - Unlock Axis.
Display Resolution Options
Spherosyn 2G or Microsyn 2G 10µm
5µm (0.0002")
10µm (0.0005")
20µm (0.001")
50µm (0.002")
Newall Measurement Systems Limited reserves the right to make changes to this specification without notice
Electrical
Physical
Environment
Accreditation
Disposal
Input & Resolutions
Microsyn 2G 5µm
1µm (0.00005")
2µm (0.0001")
5µm (0.0002")
10µm (0.0005")