Set-Up

Newall Measurement Systems

8

3.3 Direction

The direction option allows you to change the direction of travel of each axis. For example, if after installation
the X axis is measuring positive from right to left, you can use this option to change the direction of the X
axis so it measures positive from left to right.

In the Set-Up routine, press the 

until "

DIR

" (direction) is displayed. 

Each axis display will show "

0

" or "

1

Pressing each axis key 

[ Xo ] [ Yo ] 

or

[ Zo ]

reverses the counting direction.   When the unit is displaying

the choices you wish to use, press 

to continue to next option.

3.4 Radius/Diameter

This option allows you to select any axis to display measurements at a two times (x2) factor.  This is used on
lathes and other turning applications to display part diameter rather than part radius.

In the Set-Up routine, press the 

key until "

RAD

" or "

DIA

" is displayed.                

Pressing each axis key 

[ Xo ]

[ Yo ] 

or

[ Zo ]

, switches between radius and diameter readings for that axis.

When the unit is displaying the choices you wish to use, press 

]

to continue to the next option.

3.5 Linear Error Compensation

This option allows you to apply a constant correction factor to all measurements displayed.  This factor is
expressed in parts per million (PPM).

In the Set-Up routine, press the

key until LC (Linear Compensation) is displayed. The display will show

"

LC 0

" or the last correction factor entered.

To insert, or change, a correction factor, select the axis 

[ Xo ] [ Yo ] 

or

[ Zo ] 

and enter the factor you wish to

use.

The value is entered by pressing the 

and

keys

.

For example, to apply a factor of 200PPM to the X axis, press the following keys: 

[ X ] [ 

until the displays

show 200 then press

[ ent ]. 

If you make a mistake you can revert to the previous settings by pressing the

[ ce ] 

key

.  

This cancel

function will not work after the

[ ent ] 

key has been pressed.

If the unit is displaying measurements less than the actual measurement, enter a positive factor to
compensate. A factor of 200PPM means displays are measurement x 1.000200. When each axis is
displaying the correction factor you wish to use, press 

]

to return to the first option.

3.5.1 Calculating Linear Error Compensation

To establish a correction factor, check the measurements displayed by the DPG2000 against a known 
distance. The correction factor should be established while in the standard operating mode and not in the
Set-Up routine.  

Summary of Contents for DPG2000

Page 1: ...INSTALLATION USER MANUAL DPG2000 DIGITAL READOUT SYSTEM Newall Measurement Systems...

Page 2: ...Type 3 3 Direction 3 4 Radius Diameter 3 5 Linear Error Compensation 3 5 1 Calculating Linear Error Compensation 4 USER INSTRUCTIONS 4 1 Using the Keypad 5 OPERATING FUNCTIONS 5 1 Using Incremental 5...

Page 3: ...ng Voltage 115 or 230V switch selection Supply Voltage Fluctuation Not to exceed 15 of the operating voltage Supply Frequency 50 to 60 Hz Maximum Power Consumption 18VA Operating Temperature 0 to 45 C...

Page 4: ...rrangements are secure as the operator will need to apply pressure to the front panel when using the keypad An optional mounting assembly Part no 294 37740 is available which allows for tilt and rotat...

Page 5: ...lar with cable ties to ensure that it cannot drop into a hazardous position when disconnected from the cabinet The power supply cord must be routed away from moving parts swarf coolant or sources of h...

Page 6: ...connectors These connectors have a sliding sleeve that locks the connectors into their sockets Switch off the DPG2000 before connecting or disconnecting the transducers To fit the connectors into the...

Page 7: ...l self diagnostic routine When you have entered the Set Up routine the letters SET UP appear in the display The Set Up procedure makes use of a menu system The main menu consists of a list of options...

Page 8: ...ity See Section 5 6 for a description of Datahold Otherwise select SLP OFF When the selection is made press to continue to the next option 3 2 Input Type Select between Spherosyn Microsyn 5 or Microsy...

Page 9: ...Compensation This option allows you to apply a constant correction factor to all measurements displayed This factor is expressed in parts per million PPM In the Set Up routine press the key until LC L...

Page 10: ...ows For example you might use a known actual distance of 500mm against which the DPG2000 displays 499 8mm The correction factor you would then apply is 0 2mm 500mm x 1 000 000 400PPM If the DPG2000 di...

Page 11: ...xes Display Set absolute mode 30 100 140 190 5 0 OPERATING FUNCTIONS 5 1 Using Incremental a Purpose and use When the DPG2000 is set to incremental mode it can be used to display each new position rel...

Page 12: ...ach axis to within 6mm 0 25 for Spherosyn or 2 5mm 0 098 for Microsyn to the original datum point By pressing the refo followed by the corresponding axis key the display will update to a distance equa...

Page 13: ...0 has been set to Datahold the keypad will not function and the displays will be blank If the machine axis is moved DISPLACD displaced will appear in the display window The DPG2000 will record all tra...

Page 14: ...3 2 You can use the resolution function in either inch or millimetre mode The keystrokes are the same in either case The resolutions will be displayed in units corresponding to the selected mode Oper...

Page 15: ...source as above Check that all connections are sound 4 The displays work but give This suggests that the there is a poor earth ground connection erratic readings the last digit Both the DPG2000 itsel...

Page 16: ...2731 Email sales newall co uk NEWALL FRANCE SARL 63 Rue Victor Hugo F 59200 Tourcoing France T l 03 20 01 03 13 Fax 03 20 26 13 41 NEWALL ELECTRONICS INC 1778 Dividend Drive Columbus Ohio 43228 USA Te...

Reviews: