• Automatic unattended local shutdown
• Special software modules to close and save open MS-Office documents.
• Compatible for all optional modules like UPSDIALER, SNMP adapters,
Temperature sensors, etc.The UPS-Management Software is a client-/server-
application for networks and local workstations. Basically Wavemon consists of two parts: the
server-module of the UPS-Management Software is UPSMAN, which communicates via RS-232
cable with the UPS. Working as a background process the UPSMAN collects messages, received
from the UPS. The UPSMAN interprets received messages and makes them available to the client-
module UPSMON and to any SNMP-based management station.
When UPSMAN detects voltage variations or a power failure it can execute various so called
system „event routines“, which for example may shutdown the server or send warning to connected
users. These system event routines which are a part of the UPS-Management Software can be
adjusted to your demands.
The UPS management software includes with every serial number the licence for using the UPS
service on one server with one UPS and an unlimited numbers of connected WINDOWS
workstations. When operating with two or more servers a licence for every additional server is
required. It doesn’t matter if the UPS service runs at that location or if the server is halted by a UPS
service via remote command. The same regulations are applicable to the use of remote
send/receive modules RCCMD and multiserver shutdown under NT, UNIX and other operating
systems. The service programs are generally delivered as a single-licence. To use a single CD
ROM to shutdown multiple servers you have to purchase additional CD license keys.
Parallel/redundant UPS systems are also manageable by the software.
The main principle is: let introduce a shutdown of a Server only when strictly necessary. A correct
Parallel Handling has therefore to manage a parallel system as a whole and always considering
redundancy. Following statements apply:
- Every alarm on any unit is immediately notified, but …
- … a reaction to a severe fault is introduced only when the minimum number of UPS –Modules
necessary to supply the load exhibits an alarming situation.
- The real Battery autonomy time of the (whole) parallel system is computed continuously.
- Maintenance on a redundant unit may be executed without annoyance to the management system
(supervisor).
In order to be managed, a NEWAVE UPS can be integrated into a network in two ways:
1. By means of the server which is being powered by the UPS and is integrated in the network. In
most of the cases the server is used as sub-agent and you only need the Wavemon software
without any SNMP Adapter. You need a standard serial connection between the RS232 SMART
port of the UPS and the RS232 port of the computer/server.
2. In some situations it is preferable to interface the network via an SNMP adapter. By this way up
to 50 computers can be shut down in a RCCMD environment. RCCMD (Remote Console
Command) is an additional software module, which can be triggered by the SNMP device to
executes a command (typically a shutdown command) on a remote system.
Summary of Contents for 1000-3000VA
Page 13: ...4 3 Tower Configuration Setup Step 1 Step 2...
Page 14: ...Step 3 Step 4...
Page 15: ...4 4 Rack Mount Configuration Setup Step 3 Step 4 Step 5...
Page 16: ...Step 6 Step 7...
Page 19: ...4 5 6 Battery Replacement Step 1 Step 2 Step 3...
Page 20: ...Step 4...
Page 38: ...10 3 3 Installation Instructions Tower installation Stand alone unit Step 1 Step 2...
Page 39: ...Use with UPS Step 1 Step 2...
Page 40: ...10 3 4 Rack Mount installation Step 1 Step 2...
Page 41: ...Step 3 Step 4...
Page 42: ...Second Battery First Battery Bank UPS Connect DC Cable...
Page 44: ...Step 3 Step 4 10 3 7 Specifications...
Page 46: ...11 Technical Specifications...