![background image](http://html1.mh-extra.com/html/newco/bistro-touch/bistro-touch_operating-instructions-manual_1678822022.webp)
22
Load Software Update
TROUBLESHOOTING SCREENS
These error screens will display a service phone number to call if entered in “Setup” Menu (Page 15)
*Usually repairing a bad connection or replacing the indicated motor will remedy the problem.
minutes
Hysteresis cycle
Display Reads
Possible Cause(s)
Remedies
Notes
Fill Timeout Error
Water shut off to Machine
Check Water Supply Shutoff
Initial fill time longer than 8
Supply Line Blocked or too small Repair or Replace as needed
Fill time Longer than 1 Minute
Water Filter Restricted
Replace-Service Required
Water Probe has a 30 second
Inlet Solenoid valve Faulty
Replace-Service Required
Control Board Failure
Replace-Service Required
Thermistor Error Thermistor not plugged in
Make sure plug in housing is latched Open or Shorted Thermistor
Faulty Thermistor
Replacement
Control Board Failure
Replace-Service Required
Heater Error
Faulty Thermistor
Replacement
4 Minute Continuous Heater Run
Faulty Heater Element
Replace-Service Required
Control Board Failure
Replace-Service Required
Motor
Errors*
Wiring Disconnected- Pumps
Check Pump Motor Wires, Harness