background image

 

   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

LCD-2: Ambient Liquid Coffee Dispenser 

 

 

Installation 

and 

Programming 

Guide 

PN: 120463 

Summary of Contents for LCD-2

Page 1: ...LCD 2 Ambient Liquid Coffee Dispenser Installation and Programming Guide PN 120463 ...

Page 2: ...27 November 13 Phone 1 800 325 7867 Fax 1 636 925 0029 www newcocoffee com 2 This page left intentionally blank ...

Page 3: ...ace Machine on a Level Countertop Surface Connect Inch Flare water Supply to the Water Inlet located on lower Left Rear of the Machine NEWCO recommends copper tubing for use as water supply to all of our brewing equipment Turn water Supply On Plug or wire brewer to the appropriate voltage circuit as indicated on the serial tag Locate power switch on the upper right rear of the machine and turn mac...

Page 4: ...ITED TO ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE The agents dealers or employees of NEWCO are not authorized to make modifications to this warranty or to make additional warranties that are binding on NEWCO Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If NEWCO determines in it...

Page 5: ...tering in to BIB tracking mode As shown figure 2 Step 2 Enable Disable BIB Tracking This machine features the option to track the liquid output of a BIB and then alert the operator when the BIB is empty Display will flash the pump number affected and buzzer will beep if enabled To Enable BIB Tracking use the or switch to scroll until the display reads YES To disable BIB Tracking use the or switch ...

Page 6: ...igure 6 When you have made your selection press Enter to save and proceed to the next programming option SEL will appear on the display screen See figure 7 Step 4 Program Selector Switches This machine features a 7 selector switch control panel The center switch on the control panel is reserved for Hot Water Dispense The remaining 6 switches can be programmed to deliver a drink from either of the ...

Page 7: ...tor switch to create a drink using the product on the right enter the pump speed from Chart A in to Pump 2 and set the speed of Pump 1 to 0 00 Program selection blend products To program a selector switch to create a blend using both products set the speeds of Pump 1 and Pump 2 using Chart B as a guideline High Flow Rate Ratio Chart Use this chart if the unit is a high flow unit Ratio Chart A Pump...

Page 8: ...w unit Ratios Chart A Pump Speed Setting Chart B Pump Speed Settings Single Blend 45 1 5 1 1 40 1 6 2 2 35 1 7 2 2 30 1 9 3 3 25 1 11 4 4 20 1 15 6 6 15 1 24 9 9 800203 Low Flow Nozzle Small Diameter Opening 800204 High Flow Nozzle Large Diameter Opening The front nozzle determines the flow rate The back nozzle is for hot water use only ...

Page 9: ...1 will appear in the display As shown in figure 10 3 Using the or button to scroll set Pump 1 speed for the desired ratio using chart A above as a guide If blending two products use chart B as a guide As shown in figure 11 4 Press the Enter to save and proceed to set Pump 2 The number 2 and the current pump speed setting for Pump 2 will appear on the display As shown in figure 12 5 Using the or bu...

Page 10: ... 3 dashed lines The machine will be in a normal operating mode Procedure Setting Portion Control in Normal Run Mode To program a switch for portioned controls in run mode dispense time must start at 0 00 see page 9 number 6 to do this 1 Place the desired cup or carafe under the dispense head 2 Press and hold the Enter switch 3 Press and hold the selector switch that you want to program 4 After two...

Page 11: ...to 0 00 6 Press and release the Enter switch Pump 2 speed will appear in the display 7 Using the or button to scroll set Pump 2 speed to 0 00 8 Press and release the Enter switch until thee dashed lines appear in the display The switch is disabled Section 3 Service Level Programming Functions Sanitizing Instructions Press the switch to enter sanitize mode SAN will appear in the display As shown in...

Page 12: ... flows into the vessel Press and release the Enter Switch until 3 dashed lines appear in the display Discard the contents of the decanter or vessel Prime Pump Feature This feature allows you to enter directly into a Prime Pump mode without sanitizing Press the switch to enter the Prime Pump mode Follow the same Prime Pump procedures from Sanitizing Instructions BIB Counter Auto Reset Feature If en...

Page 13: ...ve the plastic insert from the BIB fitment as shown in figure 2 Using finger and thumb only to prevent over tightening thread the BIB connector on to the BIB fitment until seated as shown in figure 3 Place the product in the storage compartment as shown in figure 4 Fig 2 Fig 3 Fig 4 ...

Page 14: ...com 14 Position the tubing as shown in figure 5 Cleaning Sanitizing Instructions Remove product from storage area and disconnect BIB connectors as shown in figures 1 2 Place an empty container in the dispense area of the machine as shown in figure 3 Fig 5 Fig 2 Fig 1 Fig 3 ...

Page 15: ...n the left as you face the machine from the front and place sanitizing BIB on the product shelf as shown in figures 4 5 Press the Pump 1 button to enter sanitizing mode as shown in figure 6 Press the Pump 1 button again to begin sanitizing Sanitization cycle will run for 2 1 2 minutes Buzzer alarm will sound 3 beeps when cycle is complete Fig 6 Fig 4 Fig 5 ...

Page 16: ...ect sanitizing solution from Pump 1 and connect to the BIB connector for PUMP 2 as shown figures 7 8 Press Pump 2 button to begin sanitizing Pump as shown in figure 9 When cycle is finished remove sanitizing solution and reinstall products as shown in figure 10 Fig 7 Fig 9 Fig 10 Fig 8 ...

Page 17: ...lows from dispense head to prime pump 1 as shown in figure 11 Press enter to proceed to Pump 2 as shown in figure 12 Press and hold Pump 2 button until product flows from dispense head to prime Pump 2 as shown in figure 13 Press enter to return to the normal operating mode as shown in figure 14 Fig 11 Fig 12 Fig 13 Fig 14 ...

Page 18: ...nter button for 5 seconds until FLU appears on the display Release the Enter button Press and hold either the or button to flush the mixing chamber with water Refer to Page 3 Section 2 Figure No 2 Flush Product Type of Fittings 900044 Easy Clean Flush Solution removed from the box 400137 QCD Fitting 107117 Scholle Fitting 900044 Easy Clean Flush Solution ...

Page 19: ...r Run Error Water did not heat within timeout period Timeout period is 240 seconds which is reloaded whenever the heater is off or the fill valve is on Check element for short and proper resistance Replace if bad Er4 Tank Fill Error Water did not reach probe in timeout period of 6 minutes for initial fill and 1 minute during normal operation The 6 minute fill time is reloaded if no key is pressed ...

Page 20: ... Erb Dry Firing Tank the tank is empty but the heater is on The control board has either seen a rise in temperature of 1 degree a second for 5 seconds or has seen the temperature rise to 215 F or above The unit has been in the intent to brew timeout for an extended period of time allowing the tank to evaporate to the point where there is little water in the tank ErC Thermistor Error Resistance ext...

Page 21: ... November 13 Phone 1 800 325 7867 Fax 1 636 925 0029 www newcocoffee com 21 Dimensions Electrical Specifications Electrical Specs PN 120463 LCD 2 Ambient 120V 20 Watts 2 Amps LCD 2 LIQUID COFFEE DISPENSER ...

Page 22: ...27 November 13 Phone 1 800 325 7867 Fax 1 636 925 0029 www newcocoffee com 22 Electrical Schematics ...

Page 23: ...27 November 13 Phone 1 800 325 7867 Fax 1 636 925 0029 www newcocoffee com 23 This page left intentionally blank ...

Page 24: ...27 November 13 Phone 1 800 325 7867 Fax 1 636 925 0029 www newcocoffee com 24 This page left intentionally blank ...

Reviews: