Warning!

 

 
After transportation or keeping the device at temperature 
lower than -40

°

C (-40

°

F), the device must be warmed up to 

ambient temperature, from -10

°

C (14

°

F) to +40

°

C (104

°

F), 

relative humidity of 80% max. at 20

°

C (68

°

F). 

 

 

Precautions

 

DN-140 is a sophisticated precision optical instrument 
equipped with electronics. 
Therefore, it should be handled with due care. 

• 

Keep your device away from direct sunlight, impacts,  

 

dust, moisture, and sudden changes of temperatures. 

• 

Do not touch the optical surfaces with fingers.  Doing so  

 

may damage the anti-reflection coating. 

• 

Cleaning of optical surfaces is possible only with  

 

professional camera lens cleaning supplies. 

• 

To clean the exterior of the device, use  a soft clean cloth.   

• 

Do not take the cover off the lens if not necessary.   

• 

Keep away from heating appliances and central heating. 

• 

Make sure to switch off the unit during periods of non-
operation and when storing the device for long period of  

 

time. 

• 

Do not apply superfluous efforts at work with lens 
assembly, agile elements and thread connections. 

• 

Due to considerable optical magnification of the eye-
piece some small structures inside the tube coating in the 
form of dark and/or white points may be seen in the field 
of view which does not affect the serviceability of the 
device.; 

6.3  

Operation at night

   

 

 

AT INSUFFICIENT AMBIENT 

ILLUMINATION 

 

At insufficient ambient illumination use the 

Infra/Red illuminator (5).  Activated by rotating switch (10) 
clockwise.   
 

If brightness of the screen is decreasing, replace the 

batteries. 
 

Take out the batteries during long periods of non-

operation. 
 

7. a) USING THE DN-140 WITH A CAMERA OR A 
VIDEO CAMCORDER 

1.  Pull out the rubber eye-guard (3) out from the eye-piece 
(2). 
2.  Thread the camera adapter (optional) onto the filter 
threads of your camera’s lens. 
The camera adapter uses a 52mm thread size; a common 
filter thread size for many Nikon, Canon and Minolta lenses.  
You may purchase a step-up/step-down ring from your local 
camera store if your lens does not use 52mm filters. 
3.  Fit the other end of the Camera adapter onto the eyepiece 
socket of the scope.   Lock the adapter in place by using the 
three screws. 
4.  Connect the lens to the camera. 
5.   Make sure that you are in a dark area and that the lens  
cap is attached, switch the unit ON. 
6.  Focus the camera lens until the image is sharp. 

11 

 

 

Summary of Contents for DN-140

Page 1: ...of production ____________________ Place for seal Quality inspector ____________________ signature 16 OPERATION MANUAL NIGHT VISION RIFLE SCOPE DN 140M Camera Video Adaptable In USA 3310 Prospect Ave...

Page 2: ...REPLACE THE COVERED PRODUCT IN ACCORDANCE WITH THE TERMS SET FORTH HEREIN NEWCON EXPRESSLY DISCLAIMS ANY LOST PROFITS GENERAL SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES WHICH MAY RESULT FROM BREACH OF...

Page 3: ...isasters such as fire flood lightning improper electrical current or service other than by a NEWCON Authorized Service Postage insurance or shipping costs incurred in presenting your NEWCON product fo...

Page 4: ...ed properly Check the charge of the batteries Replace if they are weak Do not use old batteries with new ones The image does not appear in focus Bring the inspected object to the center of the image T...

Page 5: ...lens cover is on if it is daylight 3 Unscrew the windage elevation covers 9 4 Adjust the reticle by screwing the windage elevation screws up down left right Each horizontal click is 21mm 100m 3 4 100...

Page 6: ...ptical magnification of the eye piece some small structures inside the tube coating in the form of dark and or white points may be seen in the field of view which does not affect the serviceability of...

Page 7: ...teries if necessary if everything works now is a great time to fill the warranty card Note The scope will remain On for up to several minutes after the unit is shut Off This is normal 6 2 Testing of o...

Page 8: ...tery life hours 30 at 20 C Dimensions mm 6 5x2 6x3 5 Weight kg complete set 1 9 NOTE As the design is being continuously improved some descriptions may differ from those given above 8 5 CONSTRUCTION P...

Reviews: