background image

 

13.    ACCEPTANCE CERTIFICATE 
 
Image Intensifier Tube 

 

Minimum Measured 

Resolution, lines/mm 

30 

 

Photocathode sensitivity, integral, 

µ

A/ lm 

400  

Light amplification 

20,000 

 

Image Intensifier Tube Serial Number: _____________  

 Date of production: __________  

Quality Inspector Signature: ____________

 

NIGHT VISION RIFLE SCOPE     

__DN 482              __DN 483 

 
Serial Number_________ corresponds to all technical  
specifications and is admitted for use. 
 
Date of production: _____________  
 
Quality Inspector Signature: _____________ 
 
 
Quality assurance seal 
 

 
 
NEWCON

 2003                    Printed in Canada 

 
 
 
 
 
 
 

 

 
 
 

 

 
     

 

 

Operation 

Manual 

 

 
 

 
 
 

 

 

 
 

NIGHT VISION RIFLESCOPE 

DN482/483

 

(2+/3 Image Intensifier Tube generation)

 

 

  

 

 

 

In USA: 3310 Prospect Ave. Cleveland, OH 44115 

In Canada: 105 Sparks Ave., Toronto, ON M2H 2S5 Canada 

Tel: (416) 663-6963 Fax: (416) 663-9065 

Email: 

NEWCONSALES@NEWCON-OPTIK.COM 

 

Web: 

http://WWW.NEWCON-OPTIK.COM

 

 
 
 
 
 
 

Summary of Contents for DN482

Page 1: ...2 __DN 483 Serial Number_________ corresponds to all technical specifications and is admitted for use Date of production _____________ Quality Inspector Signature _____________ Quality assurance seal...

Page 2: ...alent along with proof of the date of original purchase to your Newcon Dealer Newcon will repair or at its option replace the product or part thereof which on inspection by Newcon is found to be defec...

Page 3: ...at do not affect the performance or reliability of a night vision device and some number of varying size are inherent in the manufacturing process Most of them are seen at daytime only and become almo...

Page 4: ...f trees etc 4 9 STORAGE AND MAINTENANCE INSTRUCTIONS Warning After transportation or keeping the device at temperature lower than 40 C 40 F the device must be warmed up to ambient temperature from 10...

Page 5: ...2 8 or 4 shooting is possible even at lower diaphragm settings for example 2 but the obtained pictures will have worse resolution Taking photos with a completely opened diaphragm of the objective is...

Page 6: ...out whether the aiming point coincides with the bullet hit point Make the correction again if necessary Set the protective caps into their places The device is ready for operation While performing the...

Page 7: ...h the aimed point set by the mechanical sight or LCTS Remove the rifle from scoped machine and take out LCTS Make 2 3 shots Having examined the target make necessary corrections for example in order t...

Page 8: ...ne of three positions of the switch for different IR power settings 10 25 or 75 mW If brightness of the screen is decreasing replace the batteries It s recommended to take out the batteries during lon...

Page 9: ...and let the glue calcify according to its instruction for example 24 hours for epoxy Place the scope on the rail of the rifle so that your eye coincides with the edge of the Eyepiece Guard or in case...

Page 10: ...enient observation Cut the excessive part of the rail 4 Keeping the chosen position of the device fix the feet 2 3 to the rail 4 with thwart screws 6 Degrease the A surface of the scope and the rail P...

Reviews: