10
Keeping the unit horizontally, perform one full rotation around
vertical axis within half a minute and then one full rotation around
vertical axis with device upside down during half a minute.
If one rotation does not restore calibration – perform two rotations.
The normal compass functioning will be restored.
Setting interface format
In this mode data communication standard is set. The unit can output
measurement data via RS-232 port in either PC format (description of the
proprietary format can be obtained from Newcon upon a request) or in
the format accepted by PLGF/DALGR.
To select required data format:
Select
PLGr
or PC from
SEt
menu
Pressing Action button will activate PC or PLGR format, the display
name of format that can be activated will be shown.
Gating mode
In this mode gating function is activated: here user can set the minimal
distance to the target, any object closer than the gating distance will be
ignored.
To select Gating Mode:
Select
GAtE
from
mode
menu
Minimal gating distance of 000 m will be initially set, further pressing M
button will increase gating distance by 100 m up to 3,900 m. When the
desired distance is reached – select it by pressing
Action
button.
OVER 100M
– indicates that gating is active
To deactivate gating choose gating value zero.
Note:
The gating distance can only be increased. To exit the gating
selection cycle without setting any gating distance click through full
gating range with
M
button or hold
M
button for 2 seconds.
Gating feature helps measuring remote targets in unfavourable
atmospheric and environmental conditions by eliminating reflections
from snowflakes, raindrops, industrial wires, tree branches, etc. At the
same time, if gating distance is set incorrectly, you can remove the
desirable object from measurement range.