This mechanism helps selecting the target when ranging from
behind the bushes, wires, through the falling snow, or in similar
conditions. Similarly it enables ranging a target in front of a
bigger object, such as a wire in front of the wall.
Note:
Even with target selection logic the unit may not always be
able to range the desired target as its reflectivity may be too low
to produce enough laser beam reflections for statistically reliable
calculation. A warning will be displayed if result is not
statistically reliable. See more about target reflectivity in
Additional display information
.
Individual Measurement and Scanning regimes
The unit can operate in two regimes: (1)
Individual Measurement
and (2)
Scanning
. In
Individual Measurement
regime the unit
performs single measurement when A button is pressed shortly,
in
Scanning
regime the unit repeatedly measures and displays
results every second while A button is pressed.
Scanning
or
Individual Measurement
regimes are available for
any selected mode of measurement. When two parameters are
measured in
Scanning
regime though both will be quickly
displayed, the second one may be difficult to register by eye.
Nevertheless all data is recorded and may be recalled (see
Data
Recall mode
for details.)