20
Pressing Action button will activate PC or PLGR
format, the display name of format that can be
activated will be shown.
Gating mode
In this mode gating function is activated: here user can set
the minimal distance to the target, any object closer than
the gating distance will be ignored.
To select Gating Mode:
Select
GAtE
from
mode
menu
Minimal gating distance of 000 m will be initially set,
further pressing M button will increase gating distance by
100 m up to 3,400 m. When the desired distance is
reached – select it by pressing
Action
button.
OVER 100M
– indicates that gating is active
To deactivate gating choose gating value zero.
Note:
The gating distance can only be increased. To exit
the gating selection cycle without setting any gating
distance click through full gating range with
M
button or
hold
M
button for 2 seconds.
Gating feature helps measuring remote targets in
unfavourable atmospheric and environmental conditions
by eliminating reflections from snowflakes, raindrops,
industrial wires, tree branches, etc. At the same time, if
gating distance is set incorrectly, you can remove the