background image

daytime riflescope. Thus, it is recommended to estimate if adjustment is 
required for a night vision sight in combination with daytime riflescope 
by bore sighting daytime riflescope with and without night vision 
attachment. Value of the required adjustment should be noted in clicks of 
the riflescope and shall be used each time when nigh vision sight is being 
used.  
 
RECOMMENDATION: 
Please make sure that night vision attachment is mounted on the rifle 
with the following tolerances related to position of daytime scope axis: 
- maximum permissible misalignment of optical axes shall be within  ±1 
mm in both vertical and horizontal planes  
- maximum permissible misalignment of optical axes shall with  ±1 
degree in both vertical and horizontal planes  
 
Due to manufacturing process and design of image intensifier tubes, it is 
not always possible to eliminate boresight alignment of 1MOA at 100 m, 
which could appear during shooting. It is recommended to make 10-15 
shots during the scope testing as an additional test before operation in 
real conditions. 
 

Summary of Contents for NVS 22-2XT

Page 1: ...Operation Manual NIGHT VISION RIFLESCOPE NVS 22 2XT 105 Sparks Ave Toronto ON M2H 2S5 Canada...

Page 2: ...to your health NEVER Aim active unit towards intense light sources i e lights headlamps campfires the Moon etc NEVER reverse the polarity of a battery NEVER connect the unit to external power source...

Page 3: ...n the daytime 6 5 3 Testing NVS 22 2XT at night 6 5 4 Testing NVS 22 2XT at night with day time scope 6 6 INSTALLATION ON A RIFLE 7 7 STORAGE AND MAINTENANCE 9 8 TROUBLESHOOTING 10 8 1 The scope does...

Page 4: ...ainst a light background such as snow or grass The range decreases at lower light low atmosphere transparency or if the object is positioned against dark background such as plough land desert stems of...

Page 5: ...6 1 9 10 8 5 7 11 Fig 1 1 Device body 2 Objective lens 3 Eyepiece 4 Rubber eyepiece guard 5 Battery compartment 6 Objective lens cap 7 On Off switch 8 Focus adjustment knob 9 Weaver mount 10 IR illumi...

Page 6: ...4 Infrared illuminator optional Type IR diode Power mW 75 Illumination angle degree 8 10 Illumination spectrum nm 805 Electrical parameters Power supply 2 AA batteries Voltage V 3 Continuous work time...

Page 7: ...ONS WARNING Lens cover should be always on when switching on NVS 22 2XT in bright light conditions Never aim the lens in the direction of bright light 5 1 Battery installation NVS 22 2XT requires two...

Page 8: ...evice To avoid the fatigue of the photocathode do not leave the stationary device switched on in the excessively bright environment dawn dusk daylight etc for more than 30 minutes 5 3 Testing NVS 22 2...

Page 9: ...XT With NVS 22 2XT mounted in front of the scope it may be impossible to take the scope lens cap off When mounted in front of the daytime riflescope depending on the daytime riflescope and position of...

Page 10: ...chment is mounted on the rifle with the following tolerances related to position of daytime scope axis maximum permissible misalignment of optical axes shall be within 1 mm in both vertical and horizo...

Page 11: ...ing Doing so may damage the anti reflection coating Clean optical surfaces with professional lens cleaning supplies Use only soft clean cloth to clean the exterior of the device Keep away from sources...

Page 12: ...ared If the objective lens of switched on NVS 22 2XT are exposed to bright light it automatically shuts off to protect the image intensifier tube from overload When it happens turn the unit off wait f...

Page 13: ...ce with the same or comparable model the product or part thereof which on inspection by Newcon is found to be defective in materials or workmanship What This Warranty Does Not Cover NEWCON is not resp...

Page 14: ...Eastern Standard Time Under no circumstances should the equipment be sent to Newcon without authorisation from our technical support department Newcon accepts no responsibility for unauthorized return...

Page 15: ...______________ Minimum Measured Resolution lines mm 45 Photocathode sensitivity integral A lm 400 Light amplification 25 000 The unit complies with all technical specifications and has passed the insp...

Page 16: ...NEWCON OPTIK 2010 Printed in Canada M711 16 B IV...

Reviews: