Smokes
when
lighting up.
Flue duct is cold.
Room
decompression
Burn kindling wood
to increase heat.
In houses equipped
with mechanical
ventilation, open a
window until the fire
is well established.
Smokes
while
burning.
Ventilation
insufficient
Down draught.
Room
decompression
Consult a chimney
specialist.
Check that the flue is
not obstructed,
sweep if necessary.
Install an anti-down
draught cowl.
Consult your Dealer.
In houses equipped
with Mechanical
Ventilation, an
outside air intake
must be installed for
the chimney.
Low heat output.
Incorrect Fuels.
Use fuel
Recommended.
3.5 Replacement parts
Only use replacement parts recommended by the manufacturer.
Modifications to this appliance
must not
be made.
3.6
Parts list for Knightsbridge SE and Highgrove SE multi fuel.
Spare parts
Casting iron parts
Number
Name
Dimension
Quantity Number
Name
Weight(kg) Quantity
17
Air Control Plate
352*21*4
1
5
Hob
11.69
1
19
Pull Rod Bracket
1
86
Base
11.14
1
20
Back Air Plate
75+75(trapezoid)
1
3
Front
6.7
1
24
Hexagon Head Bolts
M6*25
17
87
Rear
10.26
1
25
Gasket
Φ6*22
14
7
LH Side Panel
5.45
1
26
Stainless Steel Hexagon
Head Bolts
M6*20
2
4
RH Side Panel
5.4
1
27
Gasket
Φ6*18
7
64
Door A
10.25
1
28
Stainless Steel Countersunk
M6*30
2
13
Air Wash Cover
1.68
1