Displayed contents of Line Status, Output Status, Faults and Alarms are listed in Figure 21.

Figure 21: Displayed contents in Main Menu

 
q

 

5.6.5 Unit Specifications

To access Unit Specification menu, type 1 and press Enter on the main menu. To return to the main menu, press Esc and 

then press Enter.
It lists unit specifications as following table.

1- Unit Specifications 

Unit Model

The model name

Unit Freq

Nominal operating frequency

Input Voltage

Nominal input voltage

Output Voltage

Nominal output voltage

Output VA

The output capacity in VA

Battery Voltage

Nominal battery voltage

Max Charge Current

Maximum charging current

Panel Firmware Version

Panel board firmware version

Main Firmware Version

Main board firmware version

Hardware Version

Hardware version

IP Address

UPS IP address

 

Line Status: [Current Status]

Output Status: [Current Status]

Contact Status: [Current Status]

Ext. Fan Status: [Current Status]

Faults: [If any, otherwise blank]

Alarms: [If any, otherwise blank]

>_

Line Status Displays

Output Status Displays

Normal

Self Test

Not Good

Inverter
Buck
Boost
Normal
Off

Contact Status/ Ext. 

Fan Status Displays

Activated
Not Activated

Fault Displays

Bus Voltage
Bus Voltage Under
Bus Soft Fail
Output Short
INV Output Voltage Low
INV Output Voltage High
Over Temperature
Fan Fault
Battery Voltage High
Over Load

Fault Displays

Bus Voltage Over
Bus Voltage Under
Bus Soft Fail
AC Fail
Output Short
INV Output Voltage Low
INV Output Voltage High
Over Temperature
Fan Fault
Battery Voltage High
Battery Voltage Low
Over Charge
Battery Voltage Under
Temp Derating
Over Load
Eeprom Fault
Battery Temperature Low
Battery Temperature High
BTS Disconnect
Battery Disconnect
Site Fault

Summary of Contents for AC UPS Series

Page 1: ...1 System Architecture 4 5 6 RS232 USB interface 15 3 2 UPS Module 4 5 7 Optional SNMP card 23 3 3 MBS Module Optional 5 6 SPECIFICATIONS 23 4 INSTALLATION 5 6 1 Line Mode Specifications 23 4 1 Unpack...

Page 2: ...in a risk of electric shock or fire 4 To reduce risk of electric shock disconnect all wirings before attempting any maintenance or cleaning Turning off the unit will not reduce this risk 5 CAUTION On...

Page 3: ...e Power Supply UPS System and optional Manual Bypass Switch AC UPS BP that provides backup power when the line is unqualified These components should be mounted inside an enclosure to provide protecti...

Page 4: ...ion 5 5 9 Internal Fan The fan is to cool down the inside temperature of the UPS and is easily replaced for maintenance GND This connector is the permanent ground of the UPS Battery Connector The batt...

Page 5: ...k The output power connects to the terminal block marked with AC OUT Switch This switch selects UPS or bypass output AC Output Breaker This circuit breaker labeled OUTPUT is a resettable protective th...

Page 6: ...ease immediately notify your carrier agent and the supplier who prepared your shipment 4 2 Mounting the UPS The UPS unit can be placed in a rack with no other parts needed It can be rack mounted or se...

Page 7: ...2 cables marked as UPS IN and UPS OUT Connect these cables from MBS to the respective connectors on the UPS 2 Connect the AC input wires to the AC input terminal blocks on the MBS Ensure proper polar...

Page 8: ...ed the UPS will transfer to line mode with the output LED ON to show UPS is running from utility power Note If the UPS keeps switching between inverter and line mode because of a noisy line the settin...

Page 9: ...P xxxxVA 9 O P P xxxxWatt 10 Load xxx 11 Mode xxxxx 12 InvEV xxxxx 13 InvTM xxxx xH 14 BukEV xxxxx 15 BukTM xxxx xH 16 BstEV xxxxx 17 BstTM xxxx xH 18 C1 Off or On C2 Off or On 19 C3 Off or On C4 Off...

Page 10: ...e 714 751 0488 Fax 714 372 7930 E Mail techservice newmarpower com PoweringTheNetwork com Figure 10 Setting and Control Page Pressing the ESC SCROLL and ENTER buttons to navigate through the menus and...

Page 11: ...voltage when output voltage achieves the user programmable preset limit Battery The unit automatically transfers to battery mode when input line power is unqualified or not present Batteries provide p...

Page 12: ...has been in battery mode The total time duration the unit has been in battery mode since the latest reset The number of times the unit has been in buck mode The total time duration the unit has been...

Page 13: ...ed as below User program Ext Alarm Ext Battery Alarm Ext Fan Failed Door Unlocked AVR Feature Enable or disable Buck and Boost function Factory default setting is enable Line Qualify Set AC recovery t...

Page 14: ...ustable range is 0 480 min with 15 min increment of each click by pressing SCROLL button The default value is 120min Default UPS Restore factory settings of UPS Default SNMP Restore factory settings o...

Page 15: ...ool HyperTerminal in Windows device can communicate with computer Follow below steps to step up HyperTerminal Step 1 The path of HyperTerminal communication tool is Programs Accessories Communications...

Page 16: ...Step 6 The Name of Unit Properties screen will pop up as shown in Figure 17 Click on the Settings tab Select all columns as below figure and click ASCII Setup button Figure 16 HyperTerminal Screen Fi...

Page 17: ...SETUP 60 CONTACT C1 Current Setting is ON BATT 0 Set to ON BATT 1 Set to LOW BATT 2 Set to TIMER 3 Set to ALARM 4 Set to FAULT 5 Set to OFF 6 Set to DISABLE 0 MAIN MENU 6 PROGRAMMABLE CONTACTS SETUP...

Page 18: ...nu numbers the line status the unit s output status and any faults or alarms that may be present Figure 20 Main Menu Screen BTS Manual Bypass Switch MBS UPS Model ID xxxxxxxxxxxxxx 0 MAIN MENU 1 Unit...

Page 19: ...re version Main Firmware Version Main board firmware version Hardware Version Hardware version IP Address UPS IP address Line Status Current Status Output Status Current Status Contact Status Current...

Page 20: ...e the latest RESET BUCK Event The number of times that BUCK function activates BUCK Timer Total time that the BUCK function activates since the latest RESET BOOST Event The number of times that BOOST...

Page 21: ...tions to factory default value 47 Set Date Adjust the date 48 Set Time Adjust the time 49 Change Password Change password The factory default password is 1111 Note The password can only be changed in...

Page 22: ...Mode Line to Battery 100VAC 88 120V AC 88V AC 88 120V AC 56 Boost Low When input voltage drops between Boost Back point and Boost Low point unit will transfer to Boost Mode only when AVR is enabled No...

Page 23: ...1 0 Nominal battery voltage 48V DC 24V DC Utility Voltage Waveform Sinusoidal utility or generator Utility qualify time setting 3 10 30 seconds adjustable Nominal Input Voltage 120V AC AVR function E...

Page 24: ...able Peak Efficiency 90 No Load Power Consumption 28W 48V DC 28W 24V DC THD Bat mode 3 Full resistive load Load crest factor 3 1 rated load Overload protection 5s 125 150 load 60s 110 125 load Output...

Page 25: ...AGM 28 2 56 4V DC 27 0 54 0V DC Battery Temperature Control Charging voltage is compensated according to battery temperature 2 5mV 3 0mV 3 5mV 4 0mV per cell per C compensated coefficient adjustable C...

Page 26: ...lace MBS UPS does not return back to Line mode Line power is missing Verify if power cord from UPS IN on MBS is properly connected to the AC input terminal blocks on UPS Verify if the UPS INPUT circui...

Page 27: ...bad temperature probe connected Only use factory supplied temperature probe reading approximately 15 000 OHMS 25 C 77 F LCD text is not readable UPS fault Return to repair center Password access is NO...

Page 28: ...e 24V DC 100Ah min Backup Time 24V DC 200Ah min AC UPS 24 700 10 1807 3613 20 858 1807 30 561 1205 40 378 869 50 306 703 60 253 581 70 197 442 80 155 383 90 137 337 100 121 294 9 WARRANTY AND FACTORY...

Reviews: