FET Temperature
This value is read from the inverter via the Inverter Module and shows the current temperature of the Field Effect
Transistor board inside the Inverter.
Equalize Button
This function will take you to a screen to allow you to Equalize your batteries. Equalizing is an overcharge performed on
FLOODED LEAD ACID BATTERIES after they have been fully charged. It reverses the buildup of negative chemical
effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top.
Equalizing also helps to remove sulfate crystals that may build up on the plates. If left unchecked, a condition called
sulfation will reduce the overall capacity of the battery.
Newmar recommends that the "EQUALIZE" function be performed at a Newmar Certified Service Center.
You should never equalize AGM batteries. This will cause damage to AGM batteries.
Advanced Button
This screen is password protected to allow Qualified Service Technicians access to make changes to the
control settings. Changing these control settings to improper values can adversely affect the operation of the
control system and may cause damage to the coach.
© 2014 Copyright Newmar Corporation. All rights reserved.
p.27
Summary of Contents for King Aire 2015
Page 1: ......
Page 2: ......
Page 4: ......
Page 24: ...Spartan Lightbar Message Center 2015 Newmar King Aire Diesel Bus 22...
Page 25: ...System Initialization Sequence 2015 Newmar King Aire Diesel Bus 23...
Page 26: ...Telltale Warning Light Information 2015 Newmar King Aire Diesel Bus 24...
Page 46: ...2015 Newmar King Aire Diesel Bus 44...
Page 146: ...SilverLeaf Floor Heat screen 2 2014 Copyright Newmar Corporation All rights reserved p 61...
Page 162: ...SilverLeaf Advanced screen 2014 Copyright Newmar Corporation All rights reserved p 77...
Page 175: ...SilverLeaf Advanced screen 2014 Copyright Newmar Corporation All rights reserved p 90...