CAUTION
DO NOT
release the fresh water hose during the retraction process. Spring tension on the hose reel
can cause the hose to retract very quickly, and can cause physical harm or injury to you and damage
to your coach.
Fresh Water Valve Operation
The rotating “Fresh Water Valve”, located in the center of the water
compartment is used to pressurize the fresh water system in your unit,
as well as to fill the fresh water demand tank. When the unit is
connected to city water, the “Fresh Water Valve” is used to pressurize
the fresh water plumbing in your unit, or fill the fresh water tank, or
both. The panel is clearly labeled; simply rotate the “Fresh Water
Valve” to the appropriate position to perform the desired function. You
can monitor the fresh water tank via the small “Multiplex” display unit
located in the basement water compartment.
Domestic Hot Water
The hot water in your unit is heated by the Oasis hydronic heating system. Turning the 110
heating element on will usually provide sufficient hot water for most household chores. To
operate an appliance that uses hot water, or to assure plenty of hot water for showering, turn on
the Oasis boiler or heating elements using the E-Plex Touch Screen controls located in the front
overhead cabinet. Both heat sources (boiler and heating elements) can be used at the same time if
desired for maximum water heating capability.
Water Filtration System
Your King Aire was manufactured with a fresh water filtration system.
This system uses extruded carbon filter cartridges to remove sediment
and certain impurities from the incoming water supply. The filter
assembly is located in the basement water compartment.
To replace the filter cartridge, turn off the water supply to the RV (at
the city water connection). Unscrew the filter canister by rotating it
clockwise. Replacement filter cartridges are available through your
Authorized Newmar Dealer; have them order part number 03738.
Insert the new filter cartridge, positioning it so the opening in the
bottom of the filter seats on the molded ring at the bottom of the
canister. Reattach the canister to the filter housing by rotating the canister in a counter clockwise
direction. When replacing the filter, make certain the rubber “O-Ring” seal is properly positioned
in its groove in the cartridge housing.
An improperly seated or missing seal will cause leakage around the perimeter of the filter
housing. Use caution not to over tighten the canister when attaching it back to the housing.
Summary of Contents for King Aire Diesel Pusher 2013
Page 1: ......
Page 3: ...2013 King Aire Diesel Pusher by Newmar 2...
Page 11: ...2013 King Aire Diesel Pusher by Newmar 10...
Page 23: ...2013 King Aire Diesel Pusher by Newmar 22...
Page 28: ...2013 King Aire Diesel Pusher by Newmar 27 System Initialization Sequence...
Page 29: ...2013 King Aire Diesel Pusher by Newmar 28 Telltale Warning Light Information...
Page 45: ...2013 King Aire Diesel Pusher by Newmar 44...
Page 52: ...2013 King Aire Diesel Pusher by Newmar 51 Keyless Entry...
Page 53: ...2013 King Aire Diesel Pusher by Newmar 52...
Page 59: ...2013 King Aire Diesel Pusher by Newmar 58...
Page 63: ...2013 King Aire Diesel Pusher by Newmar 62...
Page 71: ...2013 King Aire Diesel Pusher by Newmar 70...
Page 121: ...2013 King Aire Diesel Pusher by Newmar 120...