background image

TOP VIEW

SIDE VIEW

1.89

[48.0]

BEZEL

BACKPLATE

CASE

3.78

[96.0]

3.76

[95.5]

0.76  [19.3]

4.32

[109.7]

MAX

1/8 DIN PANEL CUTOUT

0.25 [6.4] MAX
0.03 [0.8] MIN

PANEL THICKNESS

3.622 +0.032/-.000
[92.00 +0.81/-0.00]

1.772 +0.024/-.000

[45.0 +0.61/-0.00]

0.06

[1.5]

4PLCS

R

S3

P1

DISPLAY

SPAN

ZERO

W1 W2 W3

S3

A

B

C

D

E

1
2
3
4
5
6
7

RANGE SELECTION

DIMENSIONS

Voltage Input Range

S3

±199.9 mV dc

-

±1.999 V dc

A

±19.99 V dc

B

±199.9 V dc

C

Voltage operation was configured per customer order.  115 and
230 Vac operation use the same transformer and may be reversed
with simple wiring installation.

TRANSFORMER #

AC VOLTAGE

INSTALL

REMOVE

48131

115

W1, W3

W2

48131

230

W2

W1, W3

AVAILABLE OPTIONS

CALIBRATION

1.

Apply a voltage equivalent to 95% of the range selected to the
signal input. 

2.

Adjust the span pot for a reading of 1900 ±1 count.

3.

Reinstall the lens. 

Decimal Point

S1

1.999

A

19.99

B

199.9

C

1999

Store jumper above A

OPTION DESCRIPTION

PART #

230 V ac power input

Add suffix "-C1"

100 V ac power input

Add suffix "-C5"

24 V ac power input

Add suffix "-C8"

5 V dc power input

Add suffix "-C3"

7-32 V dc power input 

Add suffix "-C2"

Green LED display (instead of Red)

Add suffix "-G"

BACKPLATE

SCREWS

METER

BEZEL

LENS

PANEL WITH
1/8 DIN CUTOUT

INSTALLATION

1.

Remove the 2 phillips screws from behind the display (you don't
have to go inside the meter) holding the rectangular backplate to
the meter. Remove the backplate and set aside.

2.

Cut or punch a hole in the panel where you want the meter to
go.  The panel can be as thick as 0.25" (6.4mm) to as thin as
0.03" (0.8mm).

3.

Insert the meter into the panel cutout.

4.

From the rear of the panel, slide the backplate over the case
(smooth side out).

5.

Install the 2 phillips screws to secure the meter in 1/8 DIN
mount.  Center the meter in hole prior to tightening screws.

ZERO

SPAN

S1

A

C

B

POWER AND SIGNAL INPUT

P1

~

AC POWER

-

DC POWER

1

SIG HI (+S)

SIG HI (+S)

2

SIG LO (-S)

SIG LO (-S)

3

Hold

Hold

4

Digital Return

Digital Return

5

Earth GND (

ý

)

-DC (-)

6

Neutral (N)

+ DC (+)

7

Line (L)

No Connection (N/C)

ELECTRICAL CONNECTIONS

Reviews: