background image

ii 

 

 

Warranty 

Newport Corporation warrants that this product will be free from defects in 
material and workmanship and will comply with Newport’s published 
specifications at the time of sale for a period of one year from date of 
shipment. If found to be defective during the warranty period, the product 
will either be repaired or replaced at Newport's option.  

To exercise this warranty, write or call your local Newport office or 
representative, or contact Newport headquarters in Irvine, California. You 
will be given prompt assistance and return instructions. Send the product, 
freight prepaid, to the indicated service facility. Repairs will be made and the 
instrument returned freight prepaid. Repaired products are warranted for the 
remainder of the original warranty period or 90 days, whichever first occurs.  

Limitation of Warranty  

The above warranties do not apply to products which have been repaired or 
modified without Newport’s written approval, or products subjected to 
unusual physical, thermal or electrical stress, improper installation, misuse, 
abuse, accident or negligence in use, storage, transportation or handling. This 
warranty also does not apply to fuses, batteries, or damage from battery 
leakage.  

This warranty is in lieu of all other warranties, expressed or implied, 
including any implied warranty of merchantability or fitness for a particular 
use. Newport Corporation shall not be liable for any indirect, special, or 
consequential damages resulting from the purchase or use of its products. 

 First printing 2016 

© 2016 by Newport Corporation, Irvine, CA. All rights reserved. No part of 
this manual may be reproduced or copied without the prior written approval 
of Newport Corporation.  

This manual has been provided for information only and product 
specifications are subject to change without notice. Any change will be 
reflected in future printings.  

Newport Corporation 

1791 Deere Avenue 

 Irvine, CA, 92606 USA  

 

Part No.  90080320 Rev. A 

Summary of Contents for ACWS Series

Page 1: ...ACWS Series Air Compressor User s Manual...

Page 2: ...products which have been repaired or modified without Newport s written approval or products subjected to unusual physical thermal or electrical stress improper installation misuse abuse accident or n...

Page 3: ...p 9 2 4 2 Initial air compressor set up 9 2 5 Operation 11 2 5 1 Turn on off air compressor 11 2 5 2 Adjusting the outlet pressure 11 2 5 3 Air compressor operations 11 3 Maintenance 12 3 1 Maintenanc...

Page 4: ...iv 5 Service Form 18...

Page 5: ...ures Figure 1 Remove rubber plug and install air intake filter 9 Figure 2 Remove rubber plug on the oil pipe 10 Figure 3 Add oil and check oil level 10 Figure 4 ACWS Parts 11 Figure 5 Outlet filter bo...

Page 6: ...rve these general warnings when operating or servicing this equipment Read the operating instructions and recommendations before using the compressor Make sure the compressor is kept upright at all ti...

Page 7: ...lectric shock do not expose to rain Store indoors Do not use to supply breathing air Drain Tank monthly after use Internal rust causes tank failure and explosion It may be necessary to do more often w...

Page 8: ...of the shipping restraints They are reusable and needed for the integrity of the system during shipment 2 2 Parts List Parts included with the ACWS compressor Compressor unit with air intake filter O...

Page 9: ...er cord to possible damage CAUTION Be careful about high heat or high humidity conditions as you will need to replace the filter and oil much more frequently 2 4 2 Initial air compressor set up WARNIN...

Page 10: ...ompressor Figure 3 Add oil and check oil level 5 Fill the tank with oil until the level is aligned with the red OIL mark on the sign next to the sight glass 6 Refit the rubber plug to the oil pipe to...

Page 11: ...nimum operating pressure 6 bar 90 psi at which point the compressor automatically switches on Figure 4 A CWS Parts 2 5 2 Adjusting the outlet pressure Outlet pressure can be adjusted using the knob on...

Page 12: ...cted in the air outlet filter Clean the compressor using a soft cloth Wipe off any oil or dirt Check compressor efficiency make sure all nuts and bolts are tight check for air leaks pressure hose wear...

Page 13: ...opriate place for draining purposes Use a container underneath the drain valve to prevent spilling Slightly tilt your ACWS Series air compressor forward and release the drain valve see Figure 4 open a...

Page 14: ...the compressor to pressurize the air tank then switch off the compressor Gently pull the ring at the end of the pressure relief valve to see if air is released If so your pressure relief valve is fun...

Page 15: ...r seal and its seat with a dry cloth Refit the seal and the valve cap If leakage persists replace the valve Broken starter relay Contact customer service Faulty condenser Contact customer service Comp...

Page 16: ...r Drain and refill with correct oil Air leak Apply soapy water to joints while the air compressor is pressurized Look for air bubbles to identify the air leak Tighten up connections that has air leak...

Page 17: ...l number 2 Purchase order number 3 Complete description of the problem If components are to be returned to Newport Corporation you will be given a Return Number which you should reference in your ship...

Page 18: ...ial or manufacturing date Description Reason for return of goods please list any specific problems Please Describe the Problem Attach additional sheets as necessary Where is the Equipment Installed fa...

Reviews: