EDH0162En1040 – 06/99
3.198
MM4005
YS — Initialize variable
Usage
IMM
PGM
MIP
Syntax
xxYSnn
Parameters
Description
xx
[int]
— Variable number.
nn
[int]
— Initializing value.
Range
xx
—
1
to
100
(integers) and
101
to
120
(floats)
.
nn
—
-32767
to
32767.
Units
xx
— None.
nn
— None.
Defaults
xx
Missing: Error O.
Out of range: Error O.
Floating point: Error A.
nn
Missing: Error C.
Out of range: Error C.
Description
This command initializes a variable. When this command is received, the
specified variable
xx
is initialized to
nn
value.
NOTE
Always initialize a variable before using it. At power up or after running
other programs, the value of a variable may be unknown.
Returns
None.
Errors
A
—
Unknown message code.
C
—
Parameter out of limits.
O
—
Variable number out of range.
Rel. Commands
TY
—
Read a variable.
Example
5YS0
|
Initialize variable #5 to 0
.
5WY18|
While variable #5 is different than 18 repeat next commands.
3PR1.2, WS |
Move axis #3 incremental 1.2 units and wait for stop.
5YA1 |
Add 1 to variable #5.
WE |
End while loop.