10
11
Snow melting OFF temperature
When it is colder than this temperature the snow melting is switched OFF.
Snow melting air humidity min
When wireless outdoor temperature sensor is used the thermostat also receives air humidity level. Snow
melting function will not be activated if the air humidity is below this limit.
User program activated eco temp
During all green hours in user program the temperature is adjusted to this value.
Externally activated eco temp
When 230VAC (pilot signal) is connected to the setback input terminal the desired temperature is defined
by this parameter.
Valve protection
Valve protection turns heating ON once per week for 5 minutes even at summer time. This setting is typically
used with water carrier floor heating valves. Feature prevents the valve from getting stuck during summer.
Sensor type
Floor sensors from different manufacturers can be used. Supported types are 2k, 10k, 12.5k, 15k, 33k
NTCs. Note! In snow melting mode 33k sensor cannot be used.
Led brightness
Brightness of the Led indicator.
User program mode
AUTO enables the user program, OFF disables it.
Wireless temperature sensor
Adding a wireless BLE temperature sensor allows the best location for temperature measurement. It is also
very accurate. To add a wireless sensor you have to select it in the N-Comfort App and write the sensor
address in Network key fields.
Receive wireless eco controls
A thermostat with an external setback switch can control several other thermostats to go in setback mode.
This feature will save the user from hard wiring the Home/Away switch to many thermostats. Only the thermo-
stats with enabled
Receive wireless eco controls
and the same
Network key
will share the setback info.
Network key and Confirm Network key
Network key is used to identify the wireless temperature sensor or the group of thermostats to receive the
wireless eco controls. Both fields need to have exactly the same text string and you have to save the settings.
For the wireless sensor you can use the QR code printed on the back side of the device. Just use the camera
function in App (bottom of the screen) to read the code, then accept and save it.
2 Week schedule (User program)
User can create 24h/7d week schedule in N-Comfort App. With week schedule the user programs thermo-
stat to decrease temperature during time slots when room is not used. Comfort/eco state is indicated with
red/green led.