background image

11

Suomi

Manual Splice

Splice

Splice

Manual Splice

Splice

Splice

1.0

0.5

0.5

0.5

  MILLIMAT 150 W/m² täytyy asentaa palamattoman materiaalin alle. Tällai-

sia materiaaleja ovat mm. laatat, liuskekivi, kivi, vinyyli, linoleumi ja marmori.

 

Lisäksi seuraavat säännöt koskien lämpövastusta ovat vo-

imassa

  Lattiamateriaalin (mukaan lukien matot tai vastaavat) kokonaislämpövastus 

ei saa ylittää arvoa RSI 0,15 [m²K / W].

 

Tyypilliset RSI-arvot

 (lämpövastus [m²K / W]) lattiamateriaalin pinnassa

 

Materiaalin  

tyypillinen paksuuden  

RSI-arvo

  Keraamiset laatat  

6 mm  

RSI 0,042 

  Vinyyli/linoleumi  

4 mm  

RSI 0,044

  Laminaatti  

6–7 mm  

RSI 0,080

  Parketti  

13–16 mm  

RSI 0,090 - 0,111

  Umpipuu, tammi  

16 mm  

RSI 0,095

  Umpipuu, mänty/kuusi  

16 mm  

RSI 0 145

  Korkki  

4–8 mm  

RSI 0,083 - 0,166

  Ohut matto, synteettinen  

6 mm  

RSI 0,116

  Ohut matto, villainen  

6 mm  

RSI 0,175

  Paksu matto, villainen  

12 mm  

RSI 0,350

  Tämä tarkoittaa, että joitakin puu ja korkkilattioita ei pitäisi asentaa MILLIMAT- 

lämpömaton päälle. Samoin joitakin mattoja ei pitäisi laittaa lämmitetyille 
lattioille.

 Varoitus!

  Jotkut puulattiat ovat herkkiä lämmölle, minkä vuoksi ne saattavat haljeta ja 

kutistua eikä niitä saisi lämmittää yli lämpötilan 28 ºC. Vain lattian valmistaja 
tai toimittaja voi antaa hyväksynnän tietyn lattialämmitysjärjestelmän käytölle. 
Ota heihin yhteyttä epäselvissä tapauksissa. Lisäksi jotkut vinyyli- ja linoleumi- 
päällysteet voivat olla herkkiä lämmölle, minkä vuoksi ne voivat haalistua. 
Tämän ongelman välttämiseksi ja liian korkean lämpötilan estämiseksi lat-
tiassa voidaan asentaa rajoittava termostaatti lattia-anturin kanssa. Suositel-
tava rajoituslämpötila (mitattu kahden kaapelin välillä lattiassa) on 35 ºC. 
Huomioi myös osiossa käyttäjän opas annetut neuvot. 

8.

  Mittaa viimeisenä testauksena maaeristys ja johdinresistanssi uudestaan, 

ennen kuin yhdistät termostaattiin. Kirjaa tiedot takuulomakkeeseen. Lämpö-
kaapeli täytyy maadoittaa oikein ja vikavirtasuojaa (RCD/GFCI) täytyy 
aina käyttää, maksimilaukaisutaso 30 mA. On mahdollista kytkeä myös 
useampi lämpömatto yhteen termostaattiin, mutta varmista, että kokonaist-
eho [W] ei ylitä termostaatin rajaa.

TÄRKEÄÄ! LIITÄNTÄOHJEET

Kylmäjohtimessa on teksti, joka ilmoittaa kuparijohtimien poikkileikkauksen pinta-
alan. Tämä on joko 1,0 mm² tai 0,5 mm². Seuraavat tiedot ovat voimassa:

1,0 mm² 

Liitä normaalisti.

0,5 mm²

Jos liität yhden johtimen (0,5 mm²)  
pylväsliitäntään käyttämättä painelevyä,  
kiinnitä metallinen puristin (käytä  
puristustyökalua) kytkentäpäähän, ennen  
kuin kiristät ruuvin.

Jos liität yhden johtimen (0,5 mm²)  
pylväsliitäntään käyttämällä painelevyä,  
johdin voidaan liittää ja kiinnittää  
normaalisti 1,0 mm²:n johtimen tapaan.

Jos liität vähintään kaksi johdinta samaan  
liitäntään (tyypistä riippumatta), toimi  
seuraavasti: Kiinnitä metallinen puristin  
(käytä puristustyökalua) kaikkiin 0,5 mm²:n  
johtimiin ja kytke johdinta (johtimia)  
peittävä puristin (puristimet) liitäntään.  
Kiinnitä tämän jälkeen normaalisti.

Täytä takuulomake. Tämä lomake on osa lämpökaapelijärjestelmän koko doku-
mentaatiota ja talon omistajan tulee saada siitä kopio. 

Muutamia ohjeita
• Käyttöönotto

 

  Kun lattia on valmis, huomioi lattian tyyppi ja lattian toimittajan ohjeet liittyen 

lattialämmitysjärjestelmän käyttöönottoon/ensimmäiseen käyttöön.

• Termostaatit ja säätimet

  Sähköinen lattialämmitys tuottaa erittäin miellyttävän ja taloudellisen lämmön.  

Lattialämmitys on hieman hitaampi säätää kuin seinään asennettava lämmitys 

ja parhaat tulokset saavutetaan käytettäessä lämpötilan säätöön sähköistä 
termostaattia. Kosteissa tiloissa käytetään yleensä termostaattia vain lattia- 
anturin kanssa. Miellyttävä lämpötila paljaalle jalalle on yleensä noin 26˚C. 
Olohuoneissa ja vastaavassa käytössä sisäänrakennettu anturi tarjoaa 
tehokkaimman tavan säädellä lämpötilaa. Monet termostaatit voivat lisäksi 
käyttää lattia-anturia lämpötilan rajoittamiseen, yleensä noin 26 ˚C.

Käyttäjän opas

Jotta voidaan varmistaa mukava ja pitkäaikainen lattialämmitys, kannattaa 
seuraavia neuvoja noudattaa:
• Lämpökaapelia ei saa kytkeä päälle, ennen kuin liimalaasti / muurauslaasti 

/ tasausbetoni / betoni on luonnollisesti kovettunut.

• Termostaattia tai muuta ohjausyksikköä täytyy käyttää ja ne täytyy ohjel-

moida valmistajan ohjeiden mukaisesti.

• ÄLÄ kiinnitä ruuveja, pultteja, nauloja tai muita vastaavia lämmitettyyn  

lattiaan. Mikäli näin täytyy tehdä, pyydä apua sähköasentajalta, joka voi 
mahdollisesti paikallistaa lämpökaapeleiden sijainnin. Asennuksen doku-
mentointi sisältää myös hyödyllistä tietoa.

• Vältä korkeita lämpötiloja: 
  - Huoneissa, joissa pinta-teho on yli 100 W/m² ei saa käyttää mattoja.  

  Noudata varovaisuutta, kun asetat lattialle lämpöä eristäviä esineitä kuten 
  vaippapaketteja, vaatekasoja jne. 

  - Huoneissa, joissa pinta-teho on 100 W/m² tai alle, ole tarkkana asetetta- 

  essa lämpöä eristäviä esineitä lämmitetylle lattialle, esimerkiksi mattoja  
  ja huonekaluja, joissa ei ole jalkoja. Huomioithan, että jotkut vinyyli/ 
  linoleumilattiat ovat herkkiä lämmölle, lattiapinta saattaa haalistua  
  korkeissa lämpötiloissa. Kysy lisätietoa valmistajalta. 

  - Huonekalut tai muut pysyvät asennukset täytyy joko varustaa jaloilla, jolloin  

  lämpö pääsee vapaasti kiertämään, tai ne täytyy asentaa lattiassa  

 

  sellaisille alueille, joilla ei ole lämmitystä.

Tuotetakuu

Kaikki meidän lämpökaapelimme ja niiden osat on perusteellisesti testattu 
valmistuksen aikana. Viimeisenä testinä on korkeajännitetesti ja johdineristyksen 
mittaaminen. Vain ne yksiköt, jotka läpäisevät testit, lähetetään markkinoille.

Nexans Norway myöntää 20 vuoden takuun materiaali- ja valmistusvirheille 
kattaen asianmukaisen ja normaalin käytön ja huollon. Vian ilmaantuessa  
Nexans Norway korjaa tai vaihtaa tuotteen. Katso yksityiskohtaiset tiedot 
takuuehdoista. Takuu ei kata virheellisestä asennuksesta johtuvia vaurioita.

Jotta takuu olisi voimassa, täytyy näiden asennusohjeiden olla mukana.  
Kirjallinen lomake, joka on jokaisen kaapelilaatikon sisällä, täytyy täyttää. Näin 
taataan, että asennuksen aikana ei ole päässyt tapahtumaan vahinkoa. Mikäli 
lämpökaapeli vioittuu asennuksen aikana, täytyy se korvata uudella ennen työn 
valmistumista. 

Jotta takuu olisi voimassa, Nexans Norway:lle täytyy ilmoittaa vahingosta 30 
päivän kuluessa siitä, kun vika on havaittu ja vahinkoilmoituksen mukana on 
oltava oikein täytetty takuulomake.

Standardit/hyväksynnät

MILLIMAT on NEMKO- ja EAC-sertifioitu.

MILLIMAT on testattu vastaamaan standardeja IEC EN 60335-1,  
IEC 60335-2-96. 

Summary of Contents for N-HEAT MILLIMAT

Page 1: ...g 6 Brukerveiledning 7 Skisse av rom 19 Svenska Installationsanvisning 8 Användarmanual 9 Skiss över rummet 19 Suomi Asennusohje 10 Käyttäjän opas 1 1 Huoneen pohjakuva 19 Русский монтажу 12 Инструкция по эксплуатации 13 План комнаты 19 German Montageanleitung 14 Benutzer Handbuch 15 Skizze des Raumes 19 Follo Trykk 12 2016 v6 30042414 mbj ...

Page 2: ...2 ...

Page 3: ...be embeded into the floor Cold lead Caution Do not damage the product Check cable integrity Apply primer Start near thermostat NB Remove foil before pouring concrete Check cable integrity before pouring concrete Embed cables Install tiles Final integrity check ...

Page 4: ...edded into the heated floor and NOT inside the wall or other non heated area Install and adjust the MILLIMAT by rolling out the mat on the sub floor Beware When making adjustments Do not cut the cable only the net MILLIMAT is self adhesive and is fixed by applying a light pressure When cutting and adjusting the mat ensure that the cables are kept at the same distance from each other as the cables ...

Page 5: ...orm This form comprises part of the total documentation of the heating cable system and the house owner shall receive a copy Some advice on commissioning When the floor is finished observe the type of floor and the floor suppliers instructions with the respect to commissioning initial use of the under floor heating system thermostats and regulators Electrical underfloor heating gives a very comfor...

Page 6: ...ten slik at den kalde tillederen kan tilkobles der hvor termostaten skal stå Ved tilpasninger tilstreb å få avstand mellom kabelstrenger lik den avstanden som er mellom strengene på nettet Unngå at varmekabelen konsentreres eller krysser seg selv Skjøten mellom kald og varm leder legges i gulvet og lokal slissing i undergulv for skjøt og endeavslutning på kabelen utføres om nødvendig Dette tilpass...

Page 7: ... er det romtermostat som gir raskest regulering av varmen Bruk helst en såkalt proporsjonalregulator som gir en meget fin og jevn temperatur i rommet og på gulvet Normalt vil gulvtemperaturen begrenses til maksimalt ca 26 C Brukerveiledning Varmekabelanlegget må ikke slås på før innstøpingsmassen er fullstendig utherdet Styrings reguleringssystemet skal betjenes i henhold til leverandørens anvisni...

Page 8: ...r märkt med SPLICE Manual Splice Splice Splice SPLICE Cold Lead Hidden integrated Splice Manual Splice Oavsett skarvtyp skall den installeras i golvet och inte i väggen eller andra ickevarma utrymmen MILLIMAT rullas ut och anpassas efter golvytan genom att man klipper i nätet och vänder på mattan OBS Klipp aldrig kabeln utan bara i nätet Var noga med att det skall vara minst 3 cm mellan MILLIMAT o...

Page 9: ... en mycket behaglig och kostnadseffektiv värme Golvvärme är något mer långsam att reglera än väggmonterade värmeelement Bästa resultat uppnås genom att reglera temperaturen via en elektrisk termostat I våtutrymmen används ofta en termostat med enbart golvsensor Omkring 26 C är en behaglig golvvärme när man går barfota Användarmanual Värmekabelanläggningen får inte slås på förän gjutmassan har härd...

Page 10: ...alla matto auki aluslattian päälle Varoitus Kun asettelet ÄLÄ leikkaa kaapelia ainoastaan verkkoa MILLIMAT on itsestään kiinnittyvä ja se asennetaan paikoilleen kevyesti painelemalla Leikattaessa ja asetettaessa mattoa paikoilleen varmista että kaapelit pysyvät samalla etäisyydellä toisistaan kuin itse matossa Varmista myös että jatkos kaapelin kylmän ja lämpimän osan liitoskohta on sijoitettu sit...

Page 11: ... valmis huomioi lattian tyyppi ja lattian toimittajan ohjeet liittyen lattialämmitysjärjestelmän käyttöönottoon ensimmäiseen käyttöön Termostaatit ja säätimet Sähköinen lattialämmitys tuottaa erittäin miellyttävän ja taloudellisen lämmön Lattialämmitys on hieman hitaampi säätää kuin seinään asennettava lämmitys ja parhaat tulokset saavutetaan käytettäessä lämpötilan säätöön sähköistä termostaattia...

Page 12: ...олжна быть встроена в обогреваемый пол но НЕ в стену или в другой необогреваемый участок Уложите и выровняйте MILLIMAT раскатав мат на поверхности Внимание Во время укладки можно разрезать только сетку но не кабель Мат MILLIMAT имеет самоклеящуюся поверхность и фиксируется при небольшом давлении Разрезая и выравнивая мат следите за тем чтобы шаг между кабелями был таким же как между кабелями на се...

Page 13: ...чального использования системы теплого пола Термостаты и регуляторы Электрический подогрев пола обеспечивает очень комфортное и экономичное отопление Теплый пол требует более медленного регулирования по сравнению с настенными нагревательными устройствами Наилучшие результаты достигаются когда для регулирования температуры используется электронный термостат Во влажных помещениях как правило использ...

Page 14: ...von der Art der SPLEISSUNG muss die SPLEISSSTELLE in den beheizten Boden eingebettet werden und darf nicht in einer Wand oder anderen unbeheizten Flächen installiert werden Rollen Sie die MILLIMAT zur Ausrichtung und Installation auf dem Untergrund aus Achtung Wenn Sie Anpassungen vornehmen schneiden Sie nicht das Kabel durch sondern nur das Netz MILLIMAT ist selbstklebend und wird durch leichten ...

Page 15: ...druck enthält einen Teil der Gesamtdokumentation für das Heizkabelsystem Dem Hauseigentümer ist eine Kopie auszuhändigen Hinweise für Inbetriebnahme Ist der Boden fertiggestellt sind bei der Inbetriebnahme bzw der ersten Benutzung des Fußboden Heizsystems der Bodentyp und die Anweisungen des Bodenherstellers zu beachten Thermostate und Regler Eine elektrische Fußbodenheizung erzeugt eine sehr komf...

Page 16: ...intained in a normal and proper manner and not having been subjected to accident alteration abuse or misuse Garantivilkår Såfremt produktene har vært benyttet og vedlikeholdt på vanlig og korrekt måte garanterer Nexans Norway for en periode som starter fra det tidligste tidspunktet av ti 10 år fra garantiskjemaet som vedlegges produktet er korrekt og fullstendig utfylt eller elleve 11 år fra produ...

Page 17: ...vern Utlösningsnivå RCD GFCI jordfelsskydd Vikavirtasuoja Trip level RCD GFCI ground fault protection 30mA Jordet kabelskjerm Jordat kabelskydd Kaaplein vaippa Earthed cable screen Jordet netting Jordat hönsnät Asennusverkko Earthed chicken wire Annet spesifiser Annat specificera Muu tarkenna Other specify Maks temperatur i konstruk sjonen er begrenset til 80 C ved Max temperatur i anläg gningen ä...

Page 18: ... La température maximum en fonctionnement est fixée à 80 C par Макс температура конструкции ограничена 80 C Planung Planning Планировка Installation Installation Монтаж Begrenzungs Schutzvorrichtung spezifizieren Limite équipement de protection spécification Ограничительное защитное оборудование укажите Kontrollsystem Système de contrôle Система контроля Bezeichnung des Typs Désignation du produit...

Page 19: ...lutning SE Skiss över rummet kabeldragning Markera ut kallkabelskarven och ändavslutet FI Huoneen pohjakuva lämpökaapelin sijoittelu Merkitse liitoksen ja loppupäätteen sijainti РУ План комнаты схема укладки кабеля Пожалуйста укажите место соединения и окончания печатных символов DE Skizze des Raumes Heizkabel Layout Bitte Spleiß und Enddichtungsstelle anzeigen 19 ...

Page 20: ...anufacturing plants at Rognan Langhus and Halden The company has nearly 1 600 employ ees and is a part of the Nexans Group which has an industrial presence in 40 countries and commercial activities worldwide Nexans employs close to 26 000 people and is listed on the Paris stock exchange More information on www nexans no NEXANS BRINGS ENERGY TO LIFE Nexans Norway AS Innspurten 9 Helsfyr P O Box 645...

Reviews: